SERVOTOUGH FluegasExact Comb. Analyser  
   
02700D1  
   
CONTROLLER TYPE  
   
GEN Safe Area
EU2 Haz. Area ATEX Cat 3
EX2 Haz. Area IEC Ex Zone 2
NA2 N. American CL 1 DIV 2
   
SENSOR HEAD TYPE  
GEN Safe Area
EU2 Haz. Area ATEX Cat 3
EX2 Haz. Area IEC Ex Zone 2
   
MINI PURGE  
  Not Required
  MiniPurge ATEX Cat 3 / IEC Ex Zone 2
  Supplied by others
   
MEASUREMENT  
  Oxygen Only
  Oxygen Only, pcb Enhanced Environmental Protection
  Combustibles Only
  Combustibles Only, pcb Enhanced Environmental Protection
  Oxygen & Combustibles
  Oxygen & Combustibles, pcb Enhanced Environmental Protection
   
COMBUSTIBLES SENSOR High Sensitivity
  Sulphur Resistant
   
FLOW ALARM  
  Not Required
  Safe Area
  Haz. Area ATEX Cat 3
  Haz. Area IEC Ex Zone 2
  N. American CL 1 DIV 2
   
SUPPLY VOLTAGE  
  110V ac
  240V ac
   
SAMPLE PROBES  
  None
  0.5m SS sample probe, unsupported, open ended, <700°C/1292°F
  1.0m SS sample probe, unsupported, open ended, <700°C/1292°F
  1.5m, SS sample probe, unsupported, open ended, <700°C/1292°F (Vertical Mount Only)
  0.5m SS sample probe, unsupported, filtered, <700°C/1292°F
  1.0m SS sample probe, unsupported, filtered, <700°C/1292°F
  1.5m, SS sample probe, unsupported, filtered, <700°C/1292°F (Vertical Mount Only)
  0.5m SS sample probe, supported, filtered, with shroud,  <700°C/1292°F
  1.0m SS sample probe, supported, filtered, with shroud,  <700°C/1292°F
  1.5m SS sample probe, supported, filtered, with shroud,  <700°C/1292°F
  2.0m SS sample probe, supported, filtered, with shroud,  <700°C/1292°F
  2.5m, SS sample probe, supported, filtered, with shroud,  <700°C/1292°F
  3.0m, SS sample probe, supported, filtered, with shroud,  <700°C/1292°F
  0.5m High Temperature Alloy, sample probe, unsupported, open ended, <1000°C/1832°F
  1.0m High Temperature Alloy, sample probe, unsupported, open ended, <1000°C/1832°F
  1.5m, High Temperature Alloy, sample probe, unsupported, open ended, <800°C/1472°F  (Vertical Mount Only)
  2.0m, High Temperature Alloy, sample probe, unsupported, open ended, <700°C/1292°F  (Vertical Mount Only)
  0.5m High Temperature Alloy, sample probe, unsupported, filtered, <1000°C/1832°F
  1.0m High Temperature Alloy, sample probe, unsupported, filtered, <1000°C/1832°F
  1.5m High Temperature Alloy, sample probe, unsupported, filtered (Vertical Mount Only)
  2.0m High Temperature Alloy, sample probe, unsupported, filtered (Vertical Mount Only)
  0.6m, Ceramic, sample probe, unsupported, filtered, <1500°C/2732°F **Special - Consult Servomex
  1.1m, Ceramic, sample probe, unsupported, filtered, <1500°C/2732°F **Special - Consult Servomex
  0.5m Ceramic, sample probe, open ended, <1750°C/3182°F
  1.0m Ceramic, sample probe, open ended, <1750°C/3182°F
  1.5m Ceramic, sample probe, open ended, <1750°C/3182°F (Vertical Mount Only)
  0.5m, SS sample probe, supported, dual filtered, with shroud, <700°C/1292°F
  1.0m, SS sample probe, supported, dual filtered, with shroud, <700°C/1292°F
  1.5m, SS sample probe, supported, dual filtered, with shroud, <700°C/1292°F
  2.0m, SS sample probe, supported, dual filtered, with shroud, <700°C/1292°F
  2.5m, SS sample probe, supported, dual filtered, with shroud, <700°C/1292°F
  3.0m, SS sample probe, supported, dual filtered, with shroud, <700°C/1292°F
  0.5m, Hastelloy, sample probe, unsupported, open
  1.0m, Hastelloy, sample probe, unsupported, open
  1.5m, Hastelloy, sample probe, unsupported, open (Vertical Mount Only)
  Non Standard sample probe - refer to Servomex
   
INTERNAL FILTER 5um  
  Fitted
   
INTERNAL FLAME ARRESTORS  
  Fitted
   
   
   
ELECTRICAL CONDUIT ENTRIES  
  3/4"NPT (O2 and COe)
  M20 (O2 or COe)
  M25 (O2 and COe)
  PG13.5 (O2 or COe)
  PG21 (O2 and COe)
   
SENSOR HEAD ENCLOSURE OPTION  
  Breather Fittings
  Corrosive Purge Fittings
  Hazardous Area Purge Fittings
  Special Sensor Head Purge O2 Only - contact Servomex
  Special Sensor Head Purge Dual - contact Servomex
   
SENSOR HEAD MOUNTING OPTION  
  Standard (4"ANSI 150lbs)
  Probe Retention (excluding supported probes)
  Thermal Spacer (excluding supported probes)
  Probe Retention & Thermal Spacer (excluding supported probes)
  High Temperature Stand Off (excluding supported probes)
  High Temperature Stand Off & Probe Retention (excluding supported probes)
   
   
SENSOR HEAD ADAPTOR FLANGE OPTION  
  No Adaption (4"ANSI 150lbs)
  3" ANSI 150lbs equivalent
  DIN 65 equivalent
  DIN 80 equivalent
  JIS 65 equivalent
  JIS 80 equivalent
  Weld -On flange complete with studs (4" ANSI 150lbs equivalent)
  Model 700B/N to 2700 adaptor flange (excluding High Temperature Stand Off)
  Thermox to 2700 adaptor flange (excluding Supported Probes)
   
CONTROL UNIT MOUNTING  
  Wall Mounted
   
CONTROL UNIT ENCLOSURE OPTIONS  
  Blanking Plugs Only
  Breather Port
  Corrosive Purge Fittings
   
UTILITIES UNITS - SAFE  
  None
  Air Set (Oxygen Only)
  Air Set with Autocalibration (Single sensor)
  Air Set with Autocalibration (Dual sensor)
  Air Set with Blowback and Autocalibration (Single sensor)
  Air Set with Blowback and Autocalibration (Dual sensor)
  Air Set and Manual Calibration (Single & Dual sensor)
   
   
   
   
USER MANUALS  
  English
  French (currently undergoing translation) - Please consult Servomex
  German (currently undergoing translation) - Please consult Servomex
   
SERVICE MANUAL  
  None
  English
   
DEFAULT SOFTWARE INTERFACE LANGUAGE  
  English
  French
  German
   
   
   
   
2930A SERVOTOUGH LaserSP  
   
02930A1 SERVOTOUGH LaserSP
CONFIGURATION  
  Single Path
AREA CLASSIFICATION  
  Safe Area
  ATEX  and IECEx Cat 3 Gas (Zone 2) Cat 2 Dust (Zone 21)
  ATEX Cat. 2G (Zone 1)
  CSA general purpose
  CSA Class 1, Division 2
MEASUREMENT  
Single Path monitors Measurement
   
  CO SERVOTOUGH LaserSP Monitor (carbon monoxide)
  CO SERVOTOUGH LaserSP Monitor, low level detection limit 0.3ppm (carbon monoxide)
  CO2 SERVOTOUGH LaserSP Monitor (carbon dioxide)
  CO2 SERVOTOUGH LaserSP Monitor<400ppm (carbon dioxide)
  NH3 SERVOTOUGH LaserSP Monitor (ammonia)
  HF SERVOTOUGH LaserSP Monitor (hydrogen fluoride)
  HCl SERVOTOUGH LaserSP Monitor (hydrogen chloride)
  H2O SERVOTOUGH LaserSP Monitor 50ppm (water)
  H2S SERVOTOUGH LaserSP Monitor (hydrogen sulphide)
  CH4 SERVOTOUGH LaserSP Monitor (methane)
  HCN SERVOTOUGH LaserSP Monitor (hydrogen cyanide)
  C3H6 SERVOTOUGH LaserSP Monitor (propylene)
  C2H4O SERVOTOUGH LaserSP Monitor (ethylene oxide)
  CH2O SERVOTOUGH LaserSP Monitor (formaldehyde)
  C2H2 SERVOTOUGH LaserSP Monitor (acetylene)
  CH3I SERVOTOUGH LaserSP Monitor (methyl iodide)
  N2O SERVOTOUGH LaserSP Monitor (nitrous oxide)
  N2O SERVOTOUGH LaserSP Monitor (ppm nitrous oxide)
   
MEASURING RANGE  
  Please state
MEASUREMENT UNITS  
  mg/m3
  ppm
  % vol
   
DUAL MEASUREMENT  
  Not Required
  H2O dual gas add-on as second gas (for HF, HCl, NH3 and CO) Note: For CO only for Temp below 200C or above 700C
  Dual gas add-on CH4 option as second gas
  Dual gas, add on CO2 as second gas (for CO)
  Dual gas, add on temperature (for O2 and CO)
   
DUAL MEASURING RANGE  
  Please state
   
DUAL MEASUREMENT UNITS  
  mg/m3
  ppm
  % vol
  Celsius
   
   
  Gas Component 1
  Stream Comp 1 Normal Range
  Stream Comp 1 Low Range
  Stream Comp 1 High Range
  Process Dust (mg/m3)
  Process Flow (m3/h)
  Process Velocity (m/sec)
  Process Opacity (%)
  Stream Temperature (°C)
  Ambient Temperature (°C)
   
  Trans/Rec Cable 10m (5m supplied as standard)
  Trans/Rec Cable 15m (5m supplied as standard)
  Trans/Rec Cable 20m (5m supplied as standard)
  TU/RU Connecting Cable 5-20m (per metre). 5m supplied as standard.
   
  TU Optical Path Length L1 (mm)
  Stack Diameter L2 (mm)
  RU Optical Path Length L3 (mm)
   
PROCESS PRESSURE UNITS  
  mbar
  bar
PROCESS PRESSURE (bar)  
  Please specify
OPTICAL WINDOW PURGING  
  None (low dust)
  Instrument Air
  Fan
   
   
  N2 (low level O2)
  Steam
SUPPLY VOLTAGE  
  110Vac 50/60Hz
  220Vac 50/60Hz
  24Vdc
HIGH TEMPERATURE APPLICATIONS  
  High temp. O2/CO2/CO applications(>700C) RU Filter mounted/tested
  13606 High Temp O2 with Air Purge (>500C)
   
MOUNTING FLANGE  
  DN50/PN10 (SP Standard)
  DN80/PN10, pair
  ANSI 2"/150lbs, pair
  ANSI 3"/300lbs, pair
  ANSI 4" 150/300lbs, pair
  Other (Specify)
   
SPECIAL FLANGE O-RINGS 21031 DN50 Flange 0-ring, 65.0x10.0, PTFE (Teflon)  Max 250C
  21033 DN50 Flange 0-ring, 65.0x10.0, FKM (Viton)  Max 200C
  21034 DN80 Flange 0-ring, 95.0x10.0, FKM (Viton)  Max 200C
TU MOUNTING  
  Indoor
  Outdoor
   
CALIBRATION CELL  
  Stainless Steel (316) For corrosive gases (except HF)
  Stainless Steel (316) For corrosive gases (except HF) electropolished
  Cal cell for O2 (Al) For non-corrosive gases
  Cal cell for HF (AI/PTFE)
MEASUREMENT CELL  
  Order measurement cell as separate item: See 02930964 measurement price list below.
TRANSMISSION OUTPUT  
  Additional 4-20mA for Trans o/p
  Auxiliary board including one 4-20mA
  Second and third 4-20mA analogue output (13474 is required for this option)
ETHERNET OUTPUT  
  Ethernet Connection (without cable)
   
ADDITIONAL NETWORK CABLE  
  Network Cable 15m (including connectors) straight
  Network Cable 15m (including connectors)cross-over
TU/RU PURGING  
  None (Blanked)
  N2 Fittings (Low Level O2)
   
2nd PURGE PORT FITTING  
  Option for 2 purge fitting on each purge/alignment unit
HIGH PRESSURE WINDOW >5 BAR  
  High Pressure Window for O2 HP O2 measurement
   
ALIGNMENT TOOLS  
  Alignment jig w/target
  IR Card (not suitable for HCl, NO, Low conc CO, CO2)
   
PURGE GAS FILTRATION  
  Purge Gas Filter Unit
   
INTEGRATED SPAN CHECK  
  Span check (for non corrosive gases only) incl. switch box.  Check application feasability with Technical Centre before quoting.
  Fixed internal sealed cell (Laser tracking typically for "zero" type applications) Check application feasability with
Technical Centre before quoting.
  Span check with internal sealed cell. Check application feasability with Technical Centre before quoting.
   
2 YEARS SPARES KIT  
  2 years spares kit
   
CERTIFICATE OF ORIGIN  
  Certificate of origin (May be required for FAT by customer)