HOTWIRE VELOCITY TRANSMITTERS | |||||||
CLASS 100 - AIR VELOCITY AND TEMPERATURE TRANSMITTERS | |||||||
CTV100 air velocity and temperature transmitter. Hotwire probe length 150mm or 300mm, duct mount or remote, with 2m cable. Measuring ranges: 0 to 30 m/s and 0 to 50°C (minimum range: 0-3 m/s). 2 outputs 0-10 V or 4-20 mA with 24Vdc or 24Vca power supply. (3-4 wires). With or without 5-digit display. IP65 ABS housing. Coming in option: LCC-100 configuration software. | |||||||
OUTPUT | DISPLAY | MOUNTING | LENGTH | TYPE | REF | ||
150.300 | |||||||
4-20 mA (A) / Actif | No | Duct | 150 | CTV100-ANA150 | 13,388 | ||
300 | CTV100-ANA300 | 13,389 | |||||
Remote | 150 | CTV100-AND150 | 13,390 | ||||
300 | CTV100-AND300 | 13,391 | |||||
Yes | Duct | 150 | CTV100-AOA150 | 13,392 | |||
300 | CTV100-AOA300 | 13,393 | |||||
Remote | 150 | CTV100-AOD150 | 13,394 | ||||
300 | CTV100-AOD300 | 13,395 | |||||
0-10V (V) / Actif | No | Duct | 150 | CTV100-VNA150 | 13,396 | ||
300 | CTV100-VNA300 | 13,397 | |||||
Remote | 150 | CTV100-VND150 | 13,398 | ||||
300 | CTV100-VND300 | 13,399 | |||||
Yes | Duct | 150 | CTV100-VOA150 | 13,400 | |||
300 | CTV100-VOA300 | 13,401 | |||||
Remote | 150 | CTV100-VOD150 | 13,402 | ||||
300 | CTV100-VOD300 | 13,403 | |||||
ADDITIONAL CABLE LENGTH ON CTV100 | |||||||
DESCRIPTION | TYPE | REF | |||||
Additional cable for remote probe of CTV100 transmitters, total cable length 5m. | C-TH-5 | 14,254 | |||||
Additional cable for remote probe of CTV100 transmitters, total cable length 10m. | C-TH-10 | 14,375 | |||||
CLASS 210 - HOTWIRE AIR VELOCITY AND TEMPERATURE TRANSMITTERS | |||||||
CTV 210 air velocity and temperature transmitters. Measuring ranges: 0 to + 30 m/s and 0 to + 50 °C (minimum range: 0 to 1m/s). Stainless steel howtire interchangeable probe, length 150mm or 300 mm, with 2m cable, 2 outputs 0-10 V or 4-20 mA, 4-wire technology, RS 232 digital output, and 2 RCR relay 6A/230 Vac (on models wihout display, configuration of relay can be done with software, coming in option). Configuration of parameters via keypad (on models with display) and via software in option (on all models).WIth or without backlit alphanumeric 2-line display. IP65 ABS housing. Power supply: 24 Vdc/Vac or 115 Vac or 230 Vac. Supplied with adjustment certificate. Coming in option: LCC-300 configuration software, calibration certificate. | |||||||
POWER SUPPLY | DISPLAY | LENGTH | TYPE | REF | |||
24 Vdc ou Vac (B) | NO | 150 mm | CTV210-BN150 | 22,416 | |||
300 mm | CTV210-BN300 | 22,417 | |||||
YES | 150 mm | CTV210-BO150 | 22,418 | ||||
300 mm | CTV210-BO300 | 22,419 | |||||
115 Vac (M) | NO | 150 mm | CTV210-MN150 | 22,420 | |||
300 mm | CTV210-MN300 | 22,421 | |||||
YES | 150 mm | CTV210-MO150 | 22,422 | ||||
300 mm | CTV210-MO300 | 22,423 | |||||
230 Vac (H) | NO | 150 mm | CTV210-HN150 | 22,424 | |||
300 mm | CTV210-HN300 | 22,425 | |||||
YES | 150 mm | CTV210-HO150 | 22,426 | ||||
300 mm | CTV210-HO300 | 22,427 | |||||
CLASS 210 - AIR VELOCITY AND TEMPERATURE TRANSMITTERS - WITHOUT PROBE | |||||||
CTV210 air velocity and temperature transmitter without probe. Measuring ranges: 0 to + 30 m/s and 0 to + 50 °C (minimum range: 0 to 1m/s). 2 outputs 0-10 V or 4-20 mA, 4-wire technology, RS232 digital output and 2 RCR relay 6A/230 Vac (on models without display, configuration can be done with software coming in option). Configuration of parameters via keypad (on models with display) or via software coming in option (on all models). WIth or without backlit alphanumeric 2-line display. IP65 ABS housing. Power supply: 24 Vdc/Vac or 230 Vac. Supplied with adjustment certificate. Coming in option: LCC-300 configuration software, calibration certificate. | |||||||
POWER SUPPLY | DISPLAY | TYPE | REF | ||||
24 Vdc ou Vac (B) | NO | CTV210-BN | 22,825 | ||||
YES | CTV210-BO | 22,826 | |||||
230 Vac (H) | NO | CTV210-HN | 22,827 | ||||
YES | CTV210-HO | 22,828 | |||||
CLASS 310 - AIR VELOCITY AND TEMPERATURE TRANSMITTERS - ABS HOUSING | |||||||
CTV310 air velocity and temperature transmitter. Measuring ranges: 0 to + 30 m/s and 0 to + 50 °C (minimum range: 0 to 1m/s). Stainless steel hotwire interchangeable remote probe, length 150mm or 300 mm, with 2m cable, 2 outputs 0-10 V or 4-20 mA, 4-wire technology, RS232 digital input/output for connection with one Class 200/300 transmitter, 2 RCR relay 6A / 230 Vac (on models without display, configuration can be done with software coming in option). Configuration of parameters via keypad (on models with display) or via sotware coming in option (on all models). Power supply: 24 Vdc/Vac or 115 Vac or 230 Vac. WIth or without backlit alphanumeric 2-line display. IP65 ABS or ALU housing. Supplied with adjustment certificate. Coming in option: RS 485 MODBUS system, ZI 300 remote control, LCC-300 configuration software, and calibration certificate. | |||||||
POWER SUPPLY | DISPLAY | LENGTH | TYPE | REF | |||
24 Vdc ou Vac (B) | NO | 150 mm | CTV310-PBN150 | 22,428 | |||
300 mm | CTV310-PBN300 | 22,430 | |||||
YES | 150 mm | CTV310-PBO150 | 22,429 | ||||
300 mm | CTV310-PBO300 | 22,431 | |||||
115 Vac (M) | NO | 150 mm | CTV310-PMN150 | 22,432 | |||
300 mm | CTV310-PMN300 | 22,433 | |||||
YES | 150 mm | CTV310-PMO150 | 22,434 | ||||
300 mm | CTV310-PMO300 | 22,435 | |||||
230 Vac (H) | NO | 150 mm | CTV310-PHN150 | 22,436 | |||
300 mm | CTV310-PHN300 | 22,437 | |||||
YES | 150 mm | CTV310-PHO150 | 22,438 | ||||
300 mm | CTV310-PHO300 | 22,439 | |||||
CLASS 310 - AIR VELOCITY AND TEMPERATURE TRANSMITTERS - ALU HOUSING | |||||||
POWER SUPPLY | DISPLAY | LENGTH | TYPE | REF | |||
24 Vdc ou Vac (B) | NO | 150 mm | CTV310-ABN150 | 22440 | |||
300 mm | CTV310-ABN300 | 22441 | |||||
YES | 150 mm | CTV310-ABO150 | 22442 | ||||
300 mm | CTV310-ABO300 | 22443 | |||||
115 Vac (M) | NO | 150 mm | CTV310-AMN150 | 22444 | |||
300 mm | CTV310-AMN300 | 22445 | |||||
YES | 150 mm | CTV310-AMO150 | 22446 | ||||
300 mm | CTV310-AMO300 | 22447 | |||||
230 Vac (H) | NO | 150 mm | CTV310-AHN150 | 22448 | |||
300 mm | CTV310-AHN300 | 22449 | |||||
YES | 150 mm | CTV310-AHO150 | 22450 | ||||
300 mm | CTV310-AHO300 | 22451 | |||||
CLASS 310 - AIR VELOCITY AND TEMPERATURE TRANSMITTERS - WITHOUT PROBE | |||||||
CTV310 air velocity and temperature transmitter without probe. Measuring ranges: 0 to + 30 m/s and 0 to + 50 °C (minimum range: 0 to 1m/s). 2 outputs 0-10 V or 4-20 mA, 4-wire technology, RS232 digital input/output for connection with one Class 200/300 transmitter, 2 RCR relay 6A / 230 Vac (on models without display, configuration via software coming in option). Configuration of parameters via keypad or remote control coming in option (on models with display) or via software (on all models). Power supply: 24 Vdc/Vac or 230 Vac. With or without backlit display. IP65 ABS or ALU housing. Supplied with adjustment certificate. Coming in option: air velocity and temperature probes, RS485 MODBUS system, ZI 300 remote control, LCC-300 configuration software, and calibration certificate. | |||||||
HOUSING | POWER SUPPLY | DISPLAY | TYPE | REF | |||
ABS | 24 Vdc ou Vac (B) | NO | CTV310-PBN | 22,829 | |||
YES | CTV310-PBO | 22,830 | |||||
230 Vac (H) | NO | CTV310-PHN | 22,831 | ||||
YES | CTV310-PHO | 22,832 | |||||
ALUminium | 24 Vdc ou Vac (B) | NO | CTV310-ABN | 22,833 | |||
YES | CTV310-ABO | 22,834 | |||||
230 Vac (H) | NO | CTV310-AHN | 22,835 | ||||
YES | CTV310-AHO | 22,836 | |||||
OVER COST FOR ADDITIONAL CABLE LENGTH ON CTV210 / CTV310 | |||||||
DESCRIPTION | TYPE | REF | |||||
Additional cable for stainless steel remote probe of CTV210/310, total cable length 5m. | C-THI-5 | 14,959 | |||||
Additional cable for stainless steel remote probe of CTV210/310, total cable length 10m. | C-THI-10 | 14,960 | |||||
HOTWIRE PROBES - FOR CTV210 / CTV310 | |||||||
DESCRIPTION | TYPE | REF | |||||
Stainless steel interchangeable remote probe, length 150mm, measuring range 0 to 30 m/s and 0 to 50 °C, with 2m cable | STV-150 | 22,452 | |||||
Stainless steel interchangeable remote probe, length 300mm, measuring range 0 to 30 m/s and 0 to 50 °C, with 2m cable | STV-300 | 22,453 | |||||
STV-OMNI: omnidirectional telescopic probe, for air velocity - Temperature - (0,00 to 5 m/s, 0 to 50 °C). Resolution 0,01 m/s on all the range. Supplied with tripod, aluminium transport case and adjusting certificate. For CTV210 and 310. | STV-OMNI | 22,866 | |||||
MOUNTING ACCESSORIES FOR CTV 100 | |||||||
DESCRIPTION | TYPE | REF | |||||
BF-13 stainless steel mounting clamp for hotwire probe diam.13mm | BF-13 | 15,747 | |||||
KI-BFP-13 mounting clamp made of PETP, with compression gland, for probe diameter 13mm. | BFP-13 | 18,401 | |||||
KI-RCCT-13/12: Stainless steel cylindrical 1/2 gas sliding connection, with Teflon ferrule, for probe diam. 13mm | KI-RCCT-13/12 | 13,788 | |||||
KI-DIN/RCCT-13/12 stainless steel threaded clamp as per DIN 2566. With cylindrical 1/2 gas sliding connector, Teflon ferrule. For probe diam. 13mm. | KI-DIN/RCCT-13/12 | 13,790 | |||||
MOUNTING ACCESSORIES FOR CTV210 / CTV310 | |||||||
DESCRIPTION | TYPE | REF | |||||
BF-8 stainless steel mounting bracket. For probes diameter 8mm. | BF-8 | 15,532 | |||||
RCT-8/12 stainless steel cylindrical 1/2 sliding connection, with Teflon ferrule. For hotwire probe diameter 8mm. | RCT-8/12 | 15,266 | |||||
KI-DIN-RCTFC-8/12 stainless steel threaded clamp as per DIN 2566. With cylindrical 1/2 gas sliding connector, Teflon ferrule. For hotwire probe diam. 8mm. | KI-DIN/RCTFC-8/12 | 13,812 | |||||
CONFIGURATION ACCESSORIES | |||||||
DESCRIPTION | TYPE | REF | |||||
Configuration software for CLASS 100. Supplied with RS 232 cable | LCC-100 | 13819 | |||||
Configuration software for CLASS 200. Supplied with user manual and RS 232 cable | LCC-300 | 13820 | |||||
RS232 / USB (DB25 or DB9) adaptor for XP Windows. Supplied with driver on CD-ROM | KT-USB | 13304 | |||||
RS485 MODBUS COMMUNICATION SYSTEM | |||||||
DESCRIPTION | TYPE | REF | |||||
RS-4: MODBUS protocole, RS 485 output. For CLASS 300 | RS4 | 13817 | |||||
DIGITAL DISPLAYS | |||||||
ATT-300 multi-directional large display. ABS IP65 housing. Dimensions 240x120x60 mm. 3 4-20mA or 0-10 V inputs, 1 RS 232 input and 1 MODBUS input/output. 24 Vdc/Vac power supply. | ATT-300 | 13,848 | |||||
ATT-300-HV | 14,797 | ||||||
ATE-300-I brushed stainless steel flush-mount display. 3 4-20 mA or 0-10 V inputs, 1 RS232 input and 1 MODBUS input/output. 24 Vdc/Vac power supply. | ATE-300-I | 13,849 | |||||
ATE-300-B white lacquered flush-mount display. 3 4-20 mA or 0-10 V inputs, 1 RS232 input and 1 MODBUS input/output. 24 Vdc/Vac power supply. | ATE-300-B | 13,850 | |||||
ACCESSORIES AND OPTIONS COMMON TO ALL TRANSMITTERS | |||||||
ALTERNATING CURRENT POWER SUPPLY | |||||||
Class 2 power supply. Mounting with integrated brackets. Input voltage: 230 Vac, output voltage: 24 Vac, 100 mA intensity. For manostats and Class 50/100 transmitters. | KI-AL-100 A | 12,964 | |||||
Class 2 power supply. DIN rail mounting. Input voltage: 230 Vac. Output voltage: 24 Vac. 400 mA intensity. | KI-AL-500 A | 12,132 | |||||
DIRECT CURRENT POWER SUPPLY | |||||||
Class 2 regulated power supply. Input voltage: 230 Vac. Output voltage: 24 Vdc. 100 mA intensity. | KI-AL-100 C | 14,063 | |||||
Class 2 regulated power supply. DIN rail mounting. Input voltage: 230 Vac. Output voltage: 24 Vdc. 400 mA intensity. | KI-AL-500 C | 12,133 | |||||
CONFIGURATION ACCESSORIES | |||||||
Infrared remote control for configuration of Class 300 transmitters. | ZI 300 | 13,818 | |||||
LCC-100 configuration software for manostats and Class 50/100 transmitters. Supplied with user manual and RS232 connection cable. | LCC-100 | 13,819 | |||||
LCC-300 configuration software for Class 200/300 transmitters. Supplied with user manual and RS232 connection cable. | LCC-300 | 13,820 | |||||
KT-USB adaptor USB / RS232 (DB25 or DB9) for Windows XP. Supplied with driver on CD-ROM and user manual. | KT-USB | 13,304 | |||||
MODBUS RS485 SYSTEM | |||||||
RS485-system output. MODBUS for Class 300 transmitters. | RS4 | 13,817 | |||||
RS232 CABLE FOR CONNECTING TRANSMITTERS TOGETHER | |||||||
2m cable with 15-pin connector, for connecting Class 200/300 transmitters together. | CRS-2 | 13,821 | |||||
Same as above, 5m cable | CRS-5 | 13,822 | |||||
Same as above, 10m cable. Maximum lenght. | CRS-10 | 13,823 | |||||
RS232 / RS 485 CABLES FOR CONNECTING TRANSMITTERS TO FLUSH-MOUNT TRANSMITTERS | |||||||
2m RS232/RS485 input/output cable, with 2-point terminal block for RS485. For connecting Class 200/300 transmitters to flush-mount transmitters (ATE and CPE 300). | CLE-2 | 13,961 | |||||
Same as above, 5m cable. | CLE-5 | 13,962 | |||||
Same as above, 10m cable. Maximum lenght. | CLE-10 | 13,963 | |||||
SUB-D connector with 10cm cable and 2-point terminal block for RS485 connection. For ATE and CPE 300 flush-mount housings. | CSE | 13,964 | |||||
MOUNTING ACCESSORIES | |||||||
ABS wall-mount plate for manostats and Class 50/100 transmitters. | PF-100 | 13,824 | |||||
Stainless steel wall-mount plate for Class 200/300 transmitters. | PF-300 | 13,825 | |||||
DATA ACQUISITION SYSTEM | |||||||
ACQUISITION MODULES | |||||||
DESCRIPTION | TYPE | REF | |||||
Acquisition module with 8 analogue inputs 4-20 mA or 0-10 V + RS 485 MODBUS protocole, RS 485 MODBUS protocole output. Power supply 10-30 Vdc (127-Ohm shunts shall be available for 4-20 mA inputs: please refer to PS120). Supplied with wall-mounting system and with DIN rail fixing system | MD 100 | 15,203 | |||||
Acquisition module with 6 Pt 100 or Pt 1000 inputs + RS 485 MODBUS protocole, RS 485 MODBUS protocole output. Power supply 10-30 Vdc Supplied with wall-mount system and DIN rail fixing system. | MD 120 | 15,204 | |||||
Acquisition module with 6 NTC thermistance inputs + RS 485 MODBUS protocole, RS 485 MODBUS protocole output. Power supply 10-30 Vdc Supplied with wall-mounting system and with DIN rail fixing system. | MD 140 | 15,205 | |||||
Acquisition module with 8 Thermocouple K, J or T inputs + RS 485 MODBUS protocole, RS 485 MODBUS protocole output. Power supply 10-30 Vdc. Supplied with wall-mounting system and with DIN rail fixing system. | MD 160 | 15,206 | |||||
Acquisition module with RS 485 MODBUS protocole input, 8 RCR relay output. Power supply 10-30 Vdc. Supplied with wall-mounting system and with DIN rail fixing system. | MR 100 | 15,207 | |||||
Acquisition module with 8 TOR input, 24 V input. 2500 V isolating. Power supply 10-30 Vdc. Supplied with wall-mounting system and with DIN rail fixing system. | MD 180 | 17,284 | |||||
Acquisition module with 7-input pulse counter. 3kHz input counter (32 bits + 1 overange bit). 30V maximum input 3000 V insulation. 10-30 Vdc power supply. Supplied with wall-mounting system and with DIN rail fixing system. |
MD 190 | 21,689 | |||||
COMMUNICATION MODULES | |||||||
Converter module, RS 485 MODBUS protocole / RADIO connection over 1500m in free field. 2-unit minimum order | MC 120 | 15,210 | |||||
Converter module, RS 485 MODBUS protocole / ETHERNET. Supplied with power adapter, 1 RJ 45 2m cable, and configuration software. 2-unit minimum order | MC 100 | 15,211 | |||||
Repeater module, RS 485 MODBUS protocole, to reach 1200m network extension | MM 100 | 15,212 | |||||
SOFTWARES AND CONNECTION MODULES | |||||||
Pack of 2 softwares for Windows XP, including: 1 software for configuration, data acquisition and data display in real time (maximum of 255 MODBUS addresses) and 1 data processing software | AKIVISION | 15,213 | |||||
Software for Windows XP: for display and data processing on additional PC | AKIVISION-E | 15,214 | |||||
Connection module for PC. USB / RS 485 MODBUS protocole. 1200m maximum length. Supplied with USB cable, wall-mounting fixing and DIN rail fixing system | ML 120 | 15,215 | |||||
Connection module for PC. RS 232 / RS 485 MODBUS protocole. Power supply 10-30 Vdc. Supplied with wall-mounting system and DIN rail fixing system. | ML 100 | 15,216 | |||||
TEMPERATURE CONVERTERS | |||||||
Discount on minimum quantities only on CO-P/T and CORD-P/T | |||||||
11 => 25 | -5% | ||||||
25 => 50 | -8% | ||||||
50 and more | -12% | ||||||
UNDER-HEAD MOUNTING TEMPERATURE CONVERTERS | |||||||
CO-P Pt100 temperature converter for mounting under head. Pt100 input, 4-20 mA output. 7 to 30 Vdc power supply. Configuration with push-button or with LCC100 software (software coming as an option) Measuring range in temperature shall be confirmed on order. | CO-P | 21,880 | |||||
Converter of temperature for mounting under head type CO-T. Thermocouple input K, J, T, N, output 4-20 mA. Power supply: 7 to 30 Vdc. Configurable maxi scale : type K: - 200 °C + 1300 °C, Type J: - 100 °C + 750 °C, Type T: - 200 °C + 400 °C, Type N: - 200 °C + 1300 °C. Configuration of the scale by button or software (optional LCC-101). Working range of temperature: (to BE DEFINED) | CO-T | 22,485 | |||||
RAIL-DIN MOUNTING TEMPERATURE CONVERTERS | |||||||
Rail-din mounting temperature converter. PT100 input, 4-20 mA output. 7 to 30 Vdc power supply. Maximum configurable range: - 200 °C + 850 °C. Configuration de l'échelle par bouton poussoir ou logiciel (LCC-101 en option). Echelle de température : (A DEFINIR). | CORD-P | 22,484 | |||||
Rail-din temperature converter. Thermocouple K, J, T, N input, 4-20 mA output. 9 to 30 Vdc power supply. Maximum configurable range: Type K - 200 °C + 1300 °C, Type J - 100 °C + 750 °C, Type T: - 200 °C + 400 °C, Type N - 200 °C + 1300 °C. Configuration by push-button or by optional LCC101 software Temperature range to be confirmed on order. | CORD-T | 22,486 | |||||
LCC-101 configuration software, for CO-P Pt100 temperature transmitter. Software coming in a CD, supplied with connection cable user manual. |
LCC-101 | 22,293 |