FurnaceRange–April2012
Important:TM21RadioTelemetryCountryApprovals Pleasenotethatthesupplyof anyTM21 RadioTelemetrysystemmaybe legally restrictedto specificgeographical locations.For clarificationof latestapprovalsplease contact Datapaqbeforequoting any system containingTM21 RF(Q18,TPAQ21 or MultiPaq21).
System numbercomprises:AAB-CCC-DD
(A=IndustryB=SoftwareC=BarrierD=Logger)
Industry  
FurnaceTracker  FT
FurnaceTrackerTelemetry  FX
Software  
Insight  I
Survey  S
InsightLite  L
CABSurveyor  C
ThermalBarrier  
TB2005  024
TB2024  059
TB4005  060
TB4005+PA1245  061
TB4008  062
TB4012  063
TB4012+PA1235  064
TB4014  065
TB4015  066
TB4016  067
TB4021  068
TB4022  069
TB4023  070
TB4024  071
TB4026  073
TB4027  074
TB4032  076
TB4033  077
TB4034  078
TB4039  080
TB4041  081
TB4043  082
TB4048  086
TB4056  091
TB4056+PA1242  092
TB4063  093
TB4065  094
TB4066  095
TB4067 097
TB4068 098
TB4072 100
TB4078 101
TB4080 102
TB4101 104
TB4102 105
TB4104 107
TB4806 111
TB4810 114
TB4905 118
TB4912 119
TB4915 120
TB4926 121
TB4933 122
TB4938 123
TB4956 124
TB4081 134
TB4083 150
TB4086 161
TB4114 162
TB4113 163
TB5014 165
TB4120 177
TB4975 178
TB4980 179
TB4123 181
TB4916 183
TB4918 184
TB4090 185
TB0300 192
TB4921 195
TB4199 196
TB4192 198
TB4127 199
TB4196 200
TB4193 201
TB4203 202
TB2040 203
TB4939 208
TB4990 209
TB4991 210
TB4189 214
TB4209 217
TB4984 229
TB4985 230
TB4986 231
TB4987 232
TB4988 233
TB4095 234
TB4239 235
TB4206 236
TB4212 237
TB4224 238
TB4232 239
TB4216 245
TB4272 255
TB8007 258
TB4998 259
TB4538 269
TB4526 270
TB4533 271
TB4249 273
TB4993 274
TB3061 275
TB4526-QD 276
TB4533-QD 277
TB4538-QD 278
TB4238 280
TB4252 281
TB4256 282
TB4257 283
TB4259 284
TB4270 285
TB4994 286
TB4996 287
TB8000 288
TB4273 294
TB4626 295
TB4626-QD 296
TB4633 297
TB4633-QD 298
TB4627 299
TB4627-QD 300
TB4634 301
TB4634-QD 302
Logger  
TP2086 52
TP2089 53
TP2084 54
TP2085 55
TP2186 57
TP2189 58
TP2184 59
TP2185 60
TP2016 62
TP2019 63
TP2014 64
TP2015 65
TP2116 67
TP2119 68
TP2114 69
TP2115 70
TP2016 x 2 72
TP2019 x 2 73
TP2116 x 2 74
TP2119 x 2 75
TP2016 - TX 76
TP2019 - TX 77
TP2116 - TX 81
TP2119 - TX 82
TP2016 TX x 2 86
TP2019 TX x 2 87
TP2116 TX x 2 88
TP2119 TX x 2 89
DQ1860 95
DQ1862 97
TP2017-TX 104
TP2017 105
TP2087 108
TP2117 109
TP2117-TX 110
TP2187 111
XD0012 120
TP2016-TM 123
TP2019-TM 124
TP2014-TM 125
TP2015-TM 126
TP2116-TM 128
TP2119-TM 129
TP2114-TM 130
TP2115-TM 131
TP2016-TM x 2 133
TP2019-TM x 2 134
TP2116-TM x 2 135
TP2119-TM x 2 136
TP2017-TM 139
TP2117-TM 140
  Furnace Range
Full Price List
PART NUMBER DETAILS
  FURNACE SOFTWARE
L5030 Additional Single User License for Furnace Insight
Software
License number only.
(Software and comms cable not included).
L5130 Additional Single User License for Furnace Insight
Survey Software
License number only.
(Software and comms cable not included).
SW5030 Datapaq Insight for Furnace Tracker Software,
English
Temperature profiling and analysis software with full real-time monitoring
functionality.
Includes real time alarm functions, event marker facility, and Wizards to help the
infrequent user.
Compatible with Windows 2000, XP, Vista.
Not suitable for Windows V3.1, 95, NT4, 98, ME.
Includes communication Interface and system accessories.
SW5030+ Datapaq Insight for Furnace Software, Language
Variants
Temperature profiling and analysis software with full real-time monitoring
functionality.
Includes real time alarm functions, event marker facility, and Wizards to help the
infrequent user.
French SW5031; German SW5032; Spanish SW5033; Portuguese SW5034;
Japanese SW5035; Simplified Chinese SW5036; Italian SW5037; Korean
SW5038; Slovak SW5039; Czech SW50310; Traditional Chinese SW30311;
Russian SW50312; Vietnamese SW50314.
SW5130 Datapaq Insight for Furnace Survey Software ,
English
Temperature profiling and analysis software with full real-time monitoring
functionality.
Includes real time alarms, event marker facility, and Wizards to help the infrequent
user.
Incorporates advanced module for furnace temperature uniformity survey.
Compatible with Windows 2000, XP, Vista.
Not suitable for Windows V3.1, 95, NT4, 98, ME.
Includes communication interface and system accessories.
SW5130+ Datapaq Insight for Furnace Survey Software -
Language Variants
Temperature profiling and analysis software with full real-time monitoring
functionality.
Includes real time alarms, event marker facility, and Wizards to help the infrequent
user.
French SW5131; German SW5132; Spanish SW5133; Portuguese SW5134;
Japanese SW5135; Simplified Chinese SW5136; Italian SW5137; Korean
SW5138; Slovak SW5139; Czech SW51310; Traditional Chinese SW51311;
Russian SW51312; Vietnamese SW51314.
SW5220 Insight Lite Software English
Includes Communications Interface, Manual and License Agreement.
Compatible with Windows 2000, XP, Vista.
Not suitable for Windows V3.1, 95, NT4, 98, ME.
SW5220+ Insight Lite Software, Language Variants
Includes Communications Interface, Manual and License Agreement.
French SW5221; German SW5222; Spanish SW5223; Portuguese SW5224;
Japanese SW5225; Simplified Chinese SW5226; Italian SW5227; Korean
SW5228; Slovak SW5229; Czech SW52210; Traditional Chinese SW52211;
Russian SW52212; Vietnamese SW52214.
SW5230 Software Upgrade from:
Insight Furnace Tracker
To: Insight for Furnace Survey English
SW5230+ Software Upgrade from:
Insight Furnace Tracker
To: Insight for Furnace Survey Language Variants
French SW5231; German SW5232; Spanish SW5233; Portuguese SW5234;
Japanese SW5235; Simplified Chinese SW5236; Italian SW5237; Korean
SW5238; Slovak SW5239; Czech SW52310; Traditional Chinese SW52311;
Russian SW52312; Vietnamese SW52314.
SW5330 Datapaq Insight CAB Surveyor Software, English
Industry specific software with Wizards to help both technicians and line operators
through setup and surveying procedures.
Includes Insight for Furnace Tracker analysis software with full real-time monitoring
functionality.
Compatible with Windows 2000, XP, Vista.
Not suitable for Windows V3.1, 95, NT4, 98, ME.
SW5330+ Datapaq Insight CAB Surveyor Software, Language
Variants
Industry specific software with Wizards to help both technicians and line operators
through setup and surveying procedures.
Includes Insight for Furnace Tracker analysis software with full real-time monitoring
functionality.
French SW5331; German SW5332; Spanish SW5333; Portuguese SW5334;
Japanese SW5335; Simplified Chinese SW5336; Italian SW5337; Korean
SW5338; Slovak SW5339; Czech SW53310; Traditional Chinese SW53311;
Russian SW53312; Vietnamese SW53314.
SW5430 Software Upgrade from:
Insight Furnace Tracker
To: Insight for CAB Surveyor English
SW5430+ Software Upgrade from:
Insight Furnace Tracker
To: Insight for CAB Surveyor, Language Variants
French SW5431; German SW5432; Spanish SW5433; Portuguese SW5434;
Japanese SW5435; Simplified Chinese SW5436; Italian SW5437; Korean
SW5438; Slovak SW5439; Czech SW54310; Traditional Chinese SW54311;
Russian SW54312; Vietnamese SW54314.
UG5030 Software Upgrade from:
Any earlier version
To: Insight Furnace Tracker for Windows™
UG5130 Software Upgrade from:
Any Earlier Version
To: Insight for Furnace Survey
UG5330 Software Upgrade from:
Furnace Tracker Version 4.0 Windows™ Software
To: Insight for CAB Surveyor English
(Includes upgrade to Insight Furnace Tracker)
UG5330+ Software Upgrade from:
Furnace Tracker Version 4.0 Windows™ Software
To: Insight for CAB Surveyor, Language Variants
(Includes upgrade to Insight Furnace Tracker).
French UG5331; German UG5332; Spanish UG5333; Portuguese UG5334;
Simplified Japanese UG5335; Simplified Chinese UG5336; Italian UG5337; Korean
UG5338; Slovak UG5339; Czech UG53310; Traditional Chinese UG53311;
Russian UG53312; Vietnamese UG53314.
FURNACE LOGGERS TYPE K
DQ1860 Q18 Data Logger, 6 Channel, Type K Thermocouples,
Range -200°C to 1,370°C
Accuracy ±0.5°C.55,000 readings per channel (6 Channels Active).
Programmable time/temp trigger.
Sampling interval 0.05s to 10min.
Rechargeable NiMH Battery with Fast Charger.
USB comms port.
Dimensions: 150mm(L) x 106mm(W) x 12mm(H)
DQ1862 Q18 Data Logger, Narrow, 6 Channel, Type K
Thermocouples, Range -200°C to 1,370°C
Accuracy ±0.5°C.
55,000 readings per channel (6 Channels Active).
Programmable time/temp trigger.
Sampling interval 0.05s to 10min.
Rechargeable NiMH Battery with Fast Charger.
USB comms port.
Dimensions: 165mm(L) x 57mm(W) x 20mm(H)
TP2016 Tpaq21, 10 Channel data logger, temperature
measuring range -100°C to +1370°C, type K, 70°C
ambient temperature operation
Accuracy +/- 0.3°C*, total memory 130,000 data points over 10 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 70°C.
Uses rechargeable NiMH battery complete with charger.
Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H).
USB communications cable supplied.
*(Contact Datapaq for accuracy -100°C to -190°C).
TP2016-TM Tpaq21, 10 Channel data logger, range -100°C to
+1370°C, type K,70°C ambient temp operation.With
integral TM21 RF transmitter
Accuracy +/- 0.3°C*, total memory 130,000 data points over 10 channels.
Sampling interval 0.1s to 50 min(no telemetry),
Sampling interval 1s to 50 min(with telemetry),
Maximum operating temperature 70°C.
Rechargeable NiMH battery/charger.
Hot data protection.
Dimensions: 200mm(L) x 98mm(W) x 20mm(H).
TM21 Transmitter TX1401.
High temp signal drift compensation.
USB comms cable.
*(Contact Datapaq for accuracy -100°C to -190°C).
TP2086 Tpaq21, 8 Channel data logger, temperature
measuring range -100°C to +1370°C, type K, 70°C
ambient temperature operation
Accuracy +/- 0.3°C*, total memory 130,000 data points over 8 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 70°C.
Uses rechargeable NiMH battery complete with charger.
Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H).
USB communications cable supplied.
*(Contact Datapaq for accuracy -100°C to -190°C).
TP2116 Tpaq21, 10 Channel data logger, temperature
measuring range -100°C to +1370°C, type K, high
ambient temperature operation
Accuracy +/- 0.3°C*, total memory 130,000 data points over 10 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 110°C.
Uses replaceable high operating temperature Lithium batteries (4).
Hot data protection by non-volatile memory and software.
Dimensions: 200mm(L) x 98mm(W) x 20mm(H).
USB communications cable supplied.
*(Contact Datapaq for accuracy -100°C to -190°C).
TP2116-TM Tpaq21, 10 Channel data logger, range -100°C to
+1370°C, type K,high ambient temp operation.With
integral TM21 RF transmitter
Accuracy +/- 0.3°C*, total memory 130,000 data points over 10 channels.
Sampling interval 0.1s to 50 min(no telemetry),
Sampling interval 1s to 50 min(with telemetry),
Maximum operating temperature 110°C.
Replaceable high temp Lithium batteries x 4.
Hot data protection.
200mm(L) x 98mm(W) x 20mm(H).
TM21 Transmitter TX1401.
High temp signal drift compensation.
USB comms cable.
*(Contact Datapaq for accuracy -100°C to -190°C).
TP2186 Tpaq21, 8 Channel data logger, temperature
measuring range -100°C to +1370°C, type K, high
ambient temperature operation
Accuracy +/- 0.3°C*, total memory 130,000 data points over 8 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 110°C.
Uses replaceable high operating temperature Lithium batteries (4).
Hot data protection by non-volatile memory and software.
Dimensions: 200mm(L) x 98mm(W) x 20mm(H).
USB communications cable supplied.
*(Contact Datapaq for accuracy -100°C to -190°C).
FURNACE LOGGERS TYPE N
TP2019 Tpaq21, 10 Channel data logger, temperature
measuring range -100°C to +1300°C, type N, 70°C
ambient temperature operation
Accuracy +/- 0.4°C*, total memory 130,000 data points over 10 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 70°C.
Uses rechargeable NiMH battery complete with charger.
Hot data protection by non-volatile memory and software.
Dimensions: 200mm (L) x 98mm (W) x 20mm (H).
USB communications cable supplied.
*(Contact Datapaq for accuracy -100°C to -190°C).
TP2019-TM Tpaq21, 10 Channel data logger, range -100°C to
+1300°C, type N,70°C ambient temp operation.With
integral TM21 RF transmitter
Accuracy +/- 0.4°C*, total memory 130,000 data points over 10 channels.
Sampling interval 0.1s to 50 min(no telemetry),
Sampling interval 1s to 50 min(with telemetry),
Maximum operating temperature 70°C.
Rechargeable NiMH battery and charger.
Hot data protection.
200mm(L) x 98mm(W) x 20mm(H).
TM21 Transmitter TX1401.
High temperature signal drift compensation.
USB comms cable.
*(Contact Datapaq for accuracy -100°C to -190°C).
TP2089 Tpaq21, 8 Channel data logger, temperature
measuring range -100°C to +1300°C, type N, 70°C
ambient temperature operation
Accuracy +/- 0.4°C*, total memory 130,000 data points over 8 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 70°C.
Uses rechargeable NiMH battery complete with charger.
Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H).
USB communications cable supplied.
*(Contact Datapaq for accuracy -100°C to -190°C).
TP2119 Tpaq21, 10 Channel data logger, temperature
measuring range -100°C to +1300°C, type N, high
ambient temperature operation
Accuracy +/- 0.4°C*, total memory 130,000 data points over 10 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 110°C.
Uses replaceable high operating temperature Lithium batteries (4).
Hot data protection by non-volatile memory and software.
Dimensions: 200mm(L) x 98mm(W) x 20mm(H).
USB communications cable supplied.
*(Contact Datapaq for accuracy -100°C to -190°C).
TP2119-TM Tpaq21, 10 Channel data logger, range -100°C to
+1300°C, type N,high ambient temp operation.With
integral TM21 RF transmitter
Accuracy +/- 0.4°C*, total memory 130,000 data points over 10 channels.
Sampling interval 0.1s to 50 min(no telemetry),
Sampling interval 1s to 50 min(with telemetry),
Maximum operating temperature 110°C.
Replaceable high temp Lithium batteries x 4.
Hot data protection.
200mm(L) x 98mm(W) x 20mm(H).
TM21 Transmitter TX1401.
High temp signal drift compensation.
USB comms cable.
*(Contact Datapaq for accuracy -100°C to -190°C).
TP2189 Tpaq21, 8 Channel data logger, temperature
measuring range -100°C to +1300°C, type N, high
ambient temperature operation
Accuracy +/- 0.4°C*, total memory 130,000 data points over 8 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 110°C.
Uses replaceable high operating temperature Lithium batteries (4).
Hot data protection by non-volatile memory and software.
Dimensions: 200mm(L) x 98mm(W) x 20mm(H).
USB communications cable supplied.
*(Contact Datapaq for accuracy -100°C to -190°C).
FURNACE LOGGERS TYPE J
TP2017 Tpaq21, 10 Channel data logger, temperature
measuring range 0°C to +800°C, type J, 70°C ambient
temperature operation
Accuracy +/- 0.2°C, total memory 130,000 data points over 10 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 70°C.
Uses rechargeable NiMH battery complete with charger.
Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H).
USB communications cable supplied
TP2017-TM Tpaq21, 10 Channel data logger, range 0°C to
+800°C, type J,70°C ambient temp operation.With
integral TM21 RF transmitter
Accuracy +/- 0.2°C, total memory 130,000 data points over 10 channels.
Sampling interval 0.1s to 50 min(no telemetry),
Sampling interval 1s to 50 min(with telemetry),
Maximum operating temperature 70°C.
Rechargeable NiMH battery and charger.
Hot data protection.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H).
TM21 Transmitter TX1401.
High temperature signal drift compensation.
USB comms cable
TP2087 Tpaq21, 8 Channel data logger, temperature
measuring range 0°C to +800°C, type J, 70°C ambient
temperature operation
Accuracy +/- 0.2°C, total memory 130,000 data points over 8 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 70°C.
Uses rechargeable NiMH battery complete with charger.
Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H).
USB communications cable supplied
TP2117 Tpaq21, 10 Channel data logger, temperature
measuring range 0°C to +800°C, type J, high ambient
temperature operation
Accuracy +/- 0.2°C, total memory 130,000 data points over 10 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 110°C.
Uses replaceable high operating temperature Lithium batteries (4).
Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H).
USB communications cable supplied
TP2117-TM Tpaq21, 10 Channel data logger, range 0°C to
+800°C, type J,high ambient temp operation.With
integral TM21 RF transmitter
Accuracy +/- 0.2°C, total memory 130,000 data points over 10 channels.
Sampling interval 0.1s to 50 min(no telemetry),
Sampling interval 1s to 50 min(with telemetry)
Maximum operating temperature 110°C.
Replaceable high operating temp Lithium batteries (4).
Hot data protection.
200 mm (L) x 98 mm (W) x 20 mm (H).
TM21 Transmitter TX1401.
High temperature signal drift compensation.
USB comms cable.
TP2187 Tpaq21, 8 Channel data logger, temperature
measuring range 0°C to +800°C, type J, high ambient
temperature operation
Accuracy +/- 0.2°C, total memory 130,000 data points over 8 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 110°C.
Uses replaceable high operating temperature Lithium batteries (4).
Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H).
USB communications cable supplied.
FURNACE LOGGERS TYPE R
TP2014 Tpaq21, 10 Channel data logger, temperature
measuring range - 0°C to +1760°C, type R, 70°C
ambient temperature operation
Accuracy ±1.0°C@200°C; ±0.7°C@1000°C, total memory 130,000 data points over
10 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 70°C.
Uses rechargeable NiMH battery complete with charger.
Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H).
USB communications cable supplied (CI1031).
TP2014-TM Tpaq21, 10 Channel data logger, range - 0°C to
+1760°C, type R, 70°C ambient temp operation.With
integral TM21 RF transmitter
Accuracy ±1.0°C@200°C; ±0.7°C@1000°C, total memory 130,000 data points over
10 channels.
Sampling interval 0.1s to 50 min(no telemetry).
Sampling interval 1s to 50 min(with telemetry),
Maximum operating temperature 70°C.
Rechargeable NiMH battery and charger.
Hot data protection.
200 mm (L) x 98 mm (W) x 20 mm (H).
TM21 Transmitter TX1401.
High temperature signal drift compensation.
USB comms cable.
TP2084 Tpaq21, 8 Channel data logger, temperature
measuring range - 0°C to +1760°C, type R, 70°C
ambient temperature operation
Accuracy ±1.0°C@200°C; ±0.7°C@1000°C, total memory 130,000 data points over
8 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 70°C.
Uses rechargeable NiMH battery complete with charger.
Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H).
USB communications cable supplied (CI1031).
TP2114 Tpaq21, 10 Channel data logger, temperature
measuring range - 0°C to +1760°C, type R, high
ambient temperature operation
Accuracy ±1.0°C@200°C; ±0.7°C@1000°C, total memory 130,000 data points over
10 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 110°C.
Uses replaceable high operating temperature Lithium batteries (4).
Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H).
USB communications cable supplied (CI1033).
TP2114-TM Tpaq21, 10 Channel data logger, range - 0°C to
+1760°C, type R, high ambient temp operation.With
integral TM21 RF transmitter
Accuracy ±1.0°C@200°C; ±0.7°C@1000°C, total memory 130,000 data points over
10 channels.
Sampling interval 0.1s to 50 min(no telemetry).
Sampling interval 1s to 50 min(with telemetry),
Maximum operating temperature 110°C.
Replaceable high operating temperature Lithium batteries (4).
Hot data protection.
200 mm (L) x 98 mm (W) x 20 mm (H).
TM21 Transmitter TX1401.
High temp signal drift compensation.
USB comms cable..
TP2184 Tpaq21, 8 Channel data logger, temperature
measuring range - 0°C to +1760°C, type R, high
ambient temperature operation
Accuracy ±1.0°C@200°C; ±0.7°C@1000°C, total memory 130,000 data points over
8 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 110°C.
Uses replaceable high operating temperature Lithium batteries (4).
Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H).
USB communications cable supplied (CI1033).
FURNACE LOGGERS TYPE S
TP2015 Tpaq21, 10 Channel data logger, temperature
measuring range - 0°C to +1760°C, type S, 70°C
ambient temperature operation
Accuracy ±1.0°C@200°C; ±0.8°C@1000°C, total memory 130,000 data points over
10 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 70°C.
Uses rechargeable NiMH battery complete with charger.
Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H).
USB communications cable supplied (CI1031).
TP2015-TM Tpaq21, 10 Channel data logger, range - 0°C to
+1760°C, type S, 70°C ambient temp operation.With
integral TM21 RF transmitter
Accuracy ±1.0°C@200°C; ±0.8°C@1000°C, total memory 130,000 data points over
10 channels.
Sampling interval 0.1s to 50 min(no telemetry).
Sampling interval 1s to 50 min(with telemetry),
Maximum operating temperature 70°C.
Rechargeable NiMH battery and charger.
Hot data protection.
200 mm (L) x 98 mm (W) x 20 mm (H).
TM21 Transmitter TX1401.
High temp signal drift compensation.
USB comms cable..
TP2085 Tpaq21, 8 Channel data logger, temperature
measuring range - 0°C to +1760°C, type S, 70°C
ambient temperature operation
Accuracy ±1.0°C@200°C; ±0.8°C@1000°C, total memory 130,000 data points over
8 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 70°C.
Uses rechargeable NiMH battery complete with charger.
Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H).
USB communications cable supplied.
(CI1031).
TP2115 Tpaq21, 10 Channel data logger, temperature
measuring range - 0°C to +1760°C, type S, high
ambient temperature operation
Accuracy ±1.0°C@200°C; ±0.8°C@1000°C, total memory 130,000 data points over
10 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 110°C.
Uses replaceable high operating temperature Lithium batteries (4).
Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H).
USB communications cable supplied (CI1033).
TP2115-TM Tpaq21, 10 Channel data logger, range - 0°C to
+1760°C, type S, high ambient temp operation.With
integral TM21 RF transmitter
Accuracy ±1.0°C@200°C; ±0.8°C@1000°C, total memory 130,000 data points over
10 channels.
Sampling interval 0.1s to 50 min(no telemetry).
Sampling interval 1s to 50 min(with telemetry),
Maximum operating temperature 110°C.
Replaceable high operating temperature Lithium batteries (4).
Hot data protection.
200 mm (L) x 98 mm (W) x 20 mm (H).
TM21 Transmitter TX1401.
High temp signal drift compensation.
USB comms cable.
TP2185 Tpaq21, 8 Channel data logger, temperature
measuring range - 0°C to +1760°C, type S, high
ambient temperature operation
Accuracy ±1.0°C@200°C; ±0.8°C@1000°C, total memory 130,000 data points over
8 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 110°C.
Uses replaceable high operating temperature Lithium batteries (4).
Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H).
USB communications cable supplied (CI1033).
EXTERNAL DATA LOGGERS
XD0012 XDL12, 12 Channel Data Logger (External)
Combination of up to 3 thermocouple types, specify when ordering.
(e.g.
XD0012/10K/2S).
Accuracy: ±0.3°C Type K,J and T; ±0.4°C Type N; ±1.1°C Type R and S.
Total memory 120,000 data points over 12 channels.
Maximum operating temperature 55°C.
Sampling interval variable from 1 to 50 mins, with up to 8 sampling interval
changes possible per run.
USB communications cable supplied.
Dimensions: 340mm(L) x 330mm(W) x 80mm(H), including computer rest.
4500 SERIES THERMAL BARRIERS
TB4526 4500 Series Thermal Barrier. Recommended Data
Logger: Tpaq21 (TP2016, TP2019 etc.)
Reinforced 310 Stainless Steel construction, Microporous insulation.
Pressure equalisation designed for gas quench.
Fitted with taper lock catches.
Phase change heat sink (1 x TB9840 included).
Optional gas quench deflector shield available (TB4526A30).
Duration (air): 4.1hrs@1000°C, 5hrs@800°C, 7.6hrs@600°C.
Dimensions (without quench deflector): 254mm(H) x 363mm(W) x 570mm(L).
Weight (inc.
heat sink, without quench deflector): 40.5kg.
TB4526-QD 4500 Series Thermal Barrier. Recommended Data
Logger: Tpaq21 (TP2016, TP2019 etc.)
Reinforced 310 Stainless Steel construction, Microporous insulation.
Pressure equalisation designed for gas quench.
Fitted with taper lock catches.
Phase change heat sink (1 x TB9840 included).
Gas quench deflector shield (TB4526A30).
Duration (air): 4.1hrs@1000°C, 5hrs@800°C, 7.6hrs@600°C.
Duration (vacuum): 7hrs@1000°C, 11hrs@800°C, 15.8hrs@600°C.
Dimensions (inc.
quench deflector): 340mm(H) x 370mm(W) x 570mm(L).
Weight (inc.
heat sink and quench deflector): 48kg.
TB4533 4500 Series Thermal Barrier. Recommended Data
Logger: Tpaq21 (TP2016, TP2019 etc.)
Reinforced 310 Stainless Steel construction, Microporous insulation.
Pressure equalisation designed for gas quench.
Fitted with taper lock catches.
Phase change heat sink (1 x TB9840 included).
Optional gas quench deflector shield available (TB4533A30).
Duration (air): 6.25hrs@1000°C, 7.5hrs@800°C, 9.5hrs@600°C.
Dimensions (without quench deflector): 304mm(H) x 410mm(W) x 613mm(L).
Weight (inc.
heat sink, without quench deflector): 44kg.
TB4533-QD 4500 Series Thermal Barrier. Recommended Data
Logger: Tpaq21 (TP2016, TP2019 etc.)
Reinforced 310 Stainless Steel construction, Microporous insulation.
Pressure equalisation designed for gas quench.
Fitted with taper lock catches.
Phase change heat sink (1 x TB9840 included).
Gas quench deflector shield (TB4533A30).
Duration (air): 6.25hrs@1000°C, 7.5hrs@800°C, 9.5hrs@600°C.
Duration (vacuum): 11hrs@1000°C, 15hrs@800°C, 19hrs@600°C.
Dimensions (inc.
quench deflector): 390mm(H) x 422mm(W) x 613mm(L).
Weight (inc.
heat sink and quench deflector): 52kg.
TB4538 4500 Series Thermal Barrier. Recommended Data
Logger: Tpaq21 (TP2016, TP2019 etc.)
Reinforced 310 Stainless Steel construction, Microporous insulation.
Pressure equalisation designed for gas quench.
Fitted with taper lock catches.
Phase change heat sink (1 x TB9840 included).
Optional gas quench deflector shield available (TB4538A30).
Duration (air): 2.1hrs@1000°C, 3.1hrs@800°C, 4.5hrs@600°C.
Dimensions (without quench deflector): 217mm(H) x 290mm(W) x 522mm(L).
Weight (inc.
heat sink, without quench deflector): 30kg.
TB4538-QD 4500 Series Thermal Barrier. Recommended Data
Logger: Tpaq21 (TP2016, TP2019 etc.)
Reinforced 310 Stainless Steel construction, Microporous insulation.
Pressure equalisation designed for gas quench.
Fitted with taper lock catches.
Phase change heat sink (1 x TB9840 included).
Gas quench deflector shield (TB4538A30).
Duration (air): 2.1hrs@1000°C, 3.1hrs@800°C, 4.5hrs@600°C.
Duration (vacuum): 3.3hrs@1000°C, 6.2hrs@800°C, 9hrs@600°C.
Dimensions (inc.
quench deflector): 303mm(H) x 303mm(W) x 522mm(L).
Weight (inc.
heat sink and quench deflector): 37kg.
4600 SERIES THERMAL BARRIERS
TB4626 4600 Series Thermal Barrier.
Recommended Data Logger: Tpaq21 (TP2016,
TP2019 etc.)
Designed for high temperature operation in Vacuum furnaces up to 1200 °C with
repeated heating above 950°C and cooling cycles.Phase change heat sink (1 x
TB9840 included).Optional gas quench deflector shield available.
(TB4526A30).Duration (Nitrogen):3.25hrs@1150°C, 5hrs@800°C, 6
hrs@600°C.Duration (Vacuum) : 3.5hrs@1150°C, 6 hrs@800°C, 8 hrs@600°C.
Dims (without quench deflector): 254mm(H) x 363mm(W) x 571mm(L).Weight (inc
heat sink, without quench deflector): 41.2kg.
TB4626-QD 4600 Series Thermal Barrier.
Recommended Data Logger: Tpaq21 (TP2016,
TP2019 etc.)
Designed for high temperature operation in Vacuum furnaces up to 1200 °C with
repeated heating above 950°C and cooling cycles.Phase change heat sink (1 x
TB9840 included).Fitted gas quench deflector shield (TB4526A30).
Duration (Nitrogen):3.25hrs@1150°C, 5hrs@800°C, 6 hrs@600°C.Duration
(Vacuum) : 3.5hrs@1150°C, 6 hrs@800°C, 8 hrs@600°C.
Dims: 341mm(H) x 371mm(W) x 571mm(L).Weight (inc heat sink, with quench
deflector): 50.5kg.
TB4633 4600 Series Thermal Barrier.
Recommended Data Logger: Tpaq21 (TP2016,
TP2019 etc.)
Designed for high temperature operation in Vacuum furnaces up to 1200 °C with
repeated heating above 950°C and cooling cycles.Phase change heat sink (1 x
TB9840 included).Optional gas quench deflector shield available (TB4533A30).
Duration (Nitrogen):4.3hrs@1150°C, 6.5hrs@800°C, 8hrs@600°C.Duration
(Vacuum) : 4.8hrs@1150°C, 8.5hrs@800°C, 11hrs@600°C.
Dims (without quench deflector): 304mm(H) x 410mm(W) x 613mm(L).Weight (inc
heat sink, without quench deflector): 54.5kg.
TB4633-QD 4600 Series Thermal Barrier.
Recommended Data Logger: Tpaq21 (TP2016,
TP2019 etc.)
Designed for high temperature operation in Vacuum furnaces up to 1200 °C with
repeated heating above 950°C and cooling cycles.Phase change heat sink (1 x
TB9840 included).Fitted gas quench deflector shield (TB4533A30).
Duration (Nitrogen):4.3hrs@1150°C, 6.5hrs@800°C, 8hrs@600°C.Duration
(Vacuum) : 4.8hrs@1150°C, 8.5hrs@800°C, 11hrs@600°C.
Dims: 390mm(H) x 420mm(W) x 613mm(L).Weight (inc heat sink, with quench
deflector): 67kg.
4900 SERIES THERMAL BARRIERS
TB4905 4900 Series Thermal Barrier, Recommended Data
Logger: TP2016, DQ1860.
310 Grade Stainless Steel construction, Microporous insulation with phase change
heat sink, Mullite textile lined, User replaceable thermocouple wear strip, Datapaq
Floating Plate™ Technology.
Duration: 50min.@1000°C, 1 hour @800°C, 1 hour 15min.@600°C, 2
hours@400°C, 6 hours@200°C.
Dimensions: 129mm(H) x 247mm(W) x 409mm(L).
Length over handles: 529mm.
Weight: 13.75kg.
TB4912 4900 Series Thermal Barrier, Recommended Data
Logger: TP2016, TP2086, DQ1860.
310 Grade Stainless Steel construction, Microporous insulation with phase change
heat sink, Mullite textile lined, user replaceable thermocouple wear strip, Datapaq
Floating Plate™ Technology.
Duration: 1 hour 45min.@1000°C, 2 hours 5min.@800°C, 4 hours@600°C, 6 hours
30min.@400°C, 15 hours 30min.@200°C.
Dimensions: 174mm(H) x 296mm(W) x 411(L), Length Over Handles: 531mm.
Weight: 21Kg.
TB4915 4900 Series Thermal Barrier, Recommended Data
Logger: DQ1860.
310 Grade Stainless Steel construction, Microporous insulation with phase change
heat sink, Mullite textile lined, User replaceable thermocouple wear strip, Datapaq
Floating Plate™ Technology.
Duration: 40min.@1000°C, 50min.@800°C, 1 hours 10min.@600°C, 1 hour
50min.@400°C, 3 hours 20min.@200°C.
Dimensions: 104mm(H) x 247mm(W) x 409mm(L), 529mm (Length over handles).
Weight: 12.6kg.
TB4926 4900 Series Thermal Barrier, Recommended Data
Loggers: TP2016, DQ1860.
310 Grade Stainless Steel construction, Microporous insulation with phase change
heat sink, Mullite textile lined, User replaceable thermocouple wear strip, Datapaq
Floating Plate™ Technology.
Dimensions: 254mm(H) x 358mm(W) x 443mm(L), 563mm(Length over handles).
Duration: 4.5 hours@1000°C, 6 hours@800°C, 12 hours@400°C, 24 hours
@200°C.
Weight: 32kg.
TB4933 4900 Series Thermal Barrier.
Recommended Data Loggers: TP2016, DQ1860.
310 Grade Stainless Steel construction, Microporous insulation with phase change
heat sink, Mullite textile lined, User replaceable thermocouple wear strip, Datapaq
Floating Plate™ Technology.
Duration: 27 hours@200°C, 18 hours@400°C, 10.5 hours@600°C, 8.5
hours@800°C, 7.5 hours@1000°C.
Dimensions: 304mm(H) x 406mm(W) x 493mm(L) (613mm over handles).
Weight: 44kg.
TB4938 4900 Series Thermal Barrier, Recommended Data
Loggers: TP2016, DQ1860.
310 Grade Stainless Steel construction, Microporous insulation with phase change
heat sink, Mullite textile lined, User replaceable wear strip, Datapaq Floating Plate
™ Technology.
Dimensions: 217mm(H) x 291mm(W) x 402mm(L), 522mm(Length over handles).
Duration: 2.5 hours@1000°C, 3.75 hours@800°C, 9 hours@400°C, 18 hours
@200°C.
Weight: 26kg.
TB4956 4900 Series Thermal Barrier, Recommended Data
Loggers: TP2016, DQ1860.
310 Grade Stainless Steel construction, Microporous insulation with phase change
heat sink, Mullite textile lined, User replaceable thermocouple wear strip, Datapaq
Floating Plate™ Technology.
Duration: 1 hour 15min.@1000°C, 2 hours@800°C, 2 hours 45min.@600°C, 4
hours 15min.@400°C, 8 hours @200°C.
Dimensions: 154mm(H) x 275mm(W) x 409mm(L), 529mm(Length over handles).
Weight:17.35kg.

 

Furnace Pricelist April 2012 - Datapaq  Vietnam_ANS Vietnam Germany, USA, Asia, Vietnam, Singapore, Japan, Cambodia, Laos, Thailand, Myanmar, Indonesia, Malaysia, Singapore, China, India, Pakistan, Egypt, Iran, Jordan, Saudi Arabia, Sudan Syria, Iraq, Sudan.


Hãy liên hệ với chúng tôi để có được giá tốt nhất !

 

Công Ty TNHH TMDV Anh Nghi Sơn

| địa chỉ | D3, Đinh Tiên Hoàng, KDC Miếu Nổi, Phường 3, Quận Bình Thạnh, TPHCM

| mã số thuế | 0310692382

| điện thoại | + 84 . 8 . 3517 0401/02 | fax | +84 . 8 . 3517 0403

| email | sales.ans@ansvietnam.com ans.vina@ansvietnam.com

| website | www.ansvietnam.com www.anhnghison.com

| liên hệ trực tuyến | Skype | Yahoo