Kiln Range – April 2012
Important: TM21 Radio Telemetry Country Approvals
Please note that the supply of any TM21 Radio Telemetry system may be legally restricted to specific geographical locations. For clarification of latest approvals please contact Datapaq before quoting any system containing TM21 RF (Q18, TPAQ21 or MultiPaq21).
System number comprises: AAB-CCC-DD
(A=Industry B=Software C=Barrier D=Logger)
Industry
Kiln Tracker (Type K) KK
Kiln Tracker (Type B) KB
Kiln Tracker (Type R) KR
Kiln Tracker (Type S) KS
Kiln Tracker (Type N) KN
Software
Insight I
Insight Lite L
Thermal Barrier
TB3020 037
TB3031 042
TB3036 043
TB3801 045
TB3802 046
TB3805 048
TB3808 051
TB3823 058
TB6100-K10 136
TB6200-K10 137
TB6300-K10 138
TB6400-K10 139
TB3038 148
TB6100-K20 170
TB6200-K20 171
TB6400-K8 172
TB3829 193
TB3043 194
TB3049 215
TB3045 226
TB3050 227
TB6500-K8/10 243
TB6500-K16/20 244
Logger
TP2086 52
TP2084 54
TP2085 55
TP2088 56
TP2186 57
TP2184 59
TP2185 60
TP2188 61
TP2016 (10ch) 62
TP2014 64
TP2015 65
TP2018 66
TP2116 67
TP2114 69
TP2115 70
TP2118 71
TP2116 x 2 74
TP2016-TX 76
TP2014-TX 78
TP2015-TX 79
TP2018-TX 80
TP2116-TX 81
TP2114-TX 83
TP2115-TX 84
TP2118-TX 85
TP2116-TX x 2 88
TP2166 93
TP2164 106
TP2165 107
TP2016-TM 123
TP2014-TM 125
TP2015-TM 126
TP2018-TM 127
TP2116-TM 128
TP2114-TM 130
TP2115-TM 131
TP2118-TM 132
TP2016-TM x 2 133
TP2116-TM x 2 135
  Kiln Range
Full Price List
PART NUMBER DETAILS
  KILN SOFTWARE
L5220 Additional Single User License for Kiln Insight
Software
License number only.
(Software and comms cable not included).
SW5120 Datapaq Kiln Insight Analysis & Real-time Software
on CD-ROM, English
Includes communications interface, and system accessories.
Compatible with Windows 2000, XP, Vista.
Not suitable for Windows V3.1, 95, NT4, 98, ME.
SW5120+ Datapaq Kiln Insight Analysis & Real-time Software
on CD-ROM, Language Variants
Includes communications interface, and system accessories.
French SW5121; German SW5122; Spanish SW5123; Portuguese SW5124;
Japanese SW5125; Simplified Chinese SW5126; Italian SW5127; Korean
SW5128; Slovak SW5129; Czech SW51210; Traditional Chinese SW51211;
Russian SW51212; Vietnamese SW51214.
SW5220 Insight Lite Software English
Includes Communications Interface, Manual and License Agreement.
Compatible with Windows 2000, XP, Vista.
Not suitable for Windows V3.1, 95, NT4, 98, ME.
SW5220+ Insight Lite Software, Language Variants
Includes Communications Interface, Manual and License Agreement.
French SW5221; German SW5222; Spanish SW5223; Portuguese SW5224;
Japanese SW5225; Simplified Chinese SW5226; Italian SW5227; Korean
SW5228; Slovak SW5229; Czech SW52210; Traditional Chinese SW52211;
Russian SW52212; Vietnamese SW52214.
UG5120 Software upgrade from any other version to Kiln
Insight software
KILN LOGGERS TYPE K
TP2016 Tpaq21, 10 Channel data logger, temperature
measuring range -100°C to +1370°C, type K, 70°C
ambient temperature operation
Accuracy +/- 0.3°C*, total memory 130,000 data points over 10 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 70°C.
Uses rechargeable NiMH battery complete with charger.
Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H).
USB communications cable supplied (CI1031).
*(Contact Datapaq for accuracy -100°C to -190°C).
TP2016-TM Tpaq21, 10 Channel data logger, range -100°C to
+1370°C, type K,70°C ambient temp operation.With
integral TM21 RF transmitter
Accuracy +/- 0.3°C*, total memory 130,000 data points over 10 channels.
Sampling interval 0.1s to 50 min(no telemetry),
Sampling interval 1s to 50 min(with telemetry),
Maximum operating temperature 70°C.
Rechargeable NiMH battery/charger.
Hot data protection.
Dimensions: 200mm(L) x 98mm(W) x 20mm(H).
TM21 Transmitter TX1401.
High temp signal drift compensation.
USB comms cable.
*(Contact Datapaq for accuracy -100°C to -190°C).
TP2086 Tpaq21, 8 Channel data logger, temperature
measuring range -100°C to +1370°C, type K, 70°C
ambient temperature operation
Accuracy +/- 0.3°C*, total memory 130,000 data points over 8 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 70°C.
Uses rechargeable NiMH battery complete with charger.
Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H).
USB communications cable supplied (CI1031).
*(Contact Datapaq for accuracy -100°C to -190°C).
TP2116 Tpaq21, 10 Channel data logger, temperature
measuring range -100°C to +1370°C, type K, high
ambient temperature operation
Accuracy +/- 0.3°C*, total memory 130,000 data points over 10 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 110°C.
Uses replaceable high operating temperature Lithium batteries (4).
Hot data protection by non-volatile memory and software.
Dimensions: 200mm(L) x 98mm(W) x 20mm(H).
USB communications cable supplied.
*(Contact Datapaq for accuracy -100°C to -190°C).
TP2116-TM Tpaq21, 10 Channel data logger, range -100°C to
+1370°C, type K,high ambient temp operation.With
integral TM21 RF transmitter
Accuracy +/- 0.3°C*, total memory 130,000 data points over 10 channels.
Sampling interval 0.1s to 50 min(no telemetry),
Sampling interval 1s to 50 min(with telemetry),
Maximum operating temperature 110°C.
Replaceable high temp Lithium batteries x 4.
Hot data protection.
200mm(L) x 98mm(W) x 20mm(H).
TM21 Transmitter TX1401.
High temp signal drift compensation.
USB comms cable.
*(Contact Datapaq for accuracy -100°C to -190°C).
TP2186 Tpaq21, 8 Channel data logger, temperature
measuring range -100°C to +1370°C, type K, high
ambient temperature operation
Accuracy +/- 0.3°C*, total memory 130,000 data points over 8 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 110°C.
Uses replaceable high operating temperature Lithium batteries (4).
Hot data protection by non-volatile memory and software.
Dimensions: 200mm(L) x 98mm(W) x 20mm(H).
USB communications cable supplied.
*(Contact Datapaq for accuracy -100°C to -190°C).
KILN LOGGERS TYPE R
TP2014 Tpaq21, 10 Channel data logger, temperature
measuring range - 0°C to +1760°C, type R, 70°C
ambient temperature operation
Accuracy ±1.0°C@200°C; ±0.7°C@1000°C, total memory 130,000 data points over
10 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 70°C.
Uses rechargeable NiMH battery complete with charger.
Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H).
USB communications cable supplied (CI1031).
TP2014-TM Tpaq21, 10 Channel data logger, range - 0°C to
+1760°C, type R, 70°C ambient temp operation.With
integral TM21 RF transmitter
Accuracy ±1.0°C@200°C; ±0.7°C@1000°C, total memory 130,000 data points over
10 channels.
Sampling interval 0.1s to 50 min(no telemetry).
Sampling interval 1s to 50 min(with telemetry),
Maximum operating temperature 70°C.
Rechargeable NiMH battery and charger.
Hot data protection.
200 mm (L) x 98 mm (W) x 20 mm (H).
TM21 Transmitter TX1401.
High temperature signal drift compensation.
USB comms cable.
TP2084 Tpaq21, 8 Channel data logger, temperature
measuring range - 0°C to +1760°C, type R, 70°C
ambient temperature operation
Accuracy ±1.0°C@200°C; ±0.7°C@1000°C, total memory 130,000 data points over
8 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 70°C.
Uses rechargeable NiMH battery complete with charger.
Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H).
USB communications cable supplied (CI1031).
TP2114 Tpaq21, 10 Channel data logger, temperature
measuring range - 0°C to +1760°C, type R, high
ambient temperature operation
Accuracy ±1.0°C@200°C; ±0.7°C@1000°C, total memory 130,000 data points over
10 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 110°C.
Uses replaceable high operating temperature Lithium batteries (4).
Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H).
USB communications cable supplied (CI1033).
TP2114-TM Tpaq21, 10 Channel data logger, range - 0°C to
+1760°C, type R, high ambient temp operation.With
integral TM21 RF transmitter
Accuracy ±1.0°C@200°C; ±0.7°C@1000°C, total memory 130,000 data points over
10 channels.
Sampling interval 0.1s to 50 min(no telemetry).
Sampling interval 1s to 50 min(with telemetry),
Maximum operating temperature 110°C.
Replaceable high operating temperature Lithium batteries (4).
Hot data protection.
200 mm (L) x 98 mm (W) x 20 mm (H).
TM21 Transmitter TX1401.
High temp signal drift compensation.
USB comms cable..
TP2184 Tpaq21, 8 Channel data logger, temperature
measuring range - 0°C to +1760°C, type R, high
ambient temperature operation
Accuracy ±1.0°C@200°C; ±0.7°C@1000°C, total memory 130,000 data points over
8 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 110°C.
Uses replaceable high operating temperature Lithium batteries (4).
Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H).
USB communications cable supplied (CI1033).
KILN LOGGERS TYPE S
TP2015 Tpaq21, 10 Channel data logger, temperature
measuring range - 0°C to +1760°C, type S, 70°C
ambient temperature operation
Accuracy ±1.0°C@200°C; ±0.8°C@1000°C, total memory 130,000 data points over
10 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 70°C.
Uses rechargeable NiMH battery complete with charger.
Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H).
USB communications cable supplied (CI1031).
TP2015-TM Tpaq21, 10 Channel data logger, range - 0°C to
+1760°C, type S, 70°C ambient temp operation.With
integral TM21 RF transmitter
Accuracy ±1.0°C@200°C; ±0.8°C@1000°C, total memory 130,000 data points over
10 channels.
Sampling interval 0.1s to 50 min(no telemetry).
Sampling interval 1s to 50 min(with telemetry),
Maximum operating temperature 70°C.
Rechargeable NiMH battery and charger.
Hot data protection.
200 mm (L) x 98 mm (W) x 20 mm (H).
TM21 Transmitter TX1401.
High temp signal drift compensation.
USB comms cable..
TP2085 Tpaq21, 8 Channel data logger, temperature
measuring range - 0°C to +1760°C, type S, 70°C
ambient temperature operation
Accuracy ±1.0°C@200°C; ±0.8°C@1000°C, total memory 130,000 data points over
8 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 70°C.
Uses rechargeable NiMH battery complete with charger.
Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H).
USB communications cable supplied.
(CI1031).
TP2115 Tpaq21, 10 Channel data logger, temperature
measuring range - 0°C to +1760°C, type S, high
ambient temperature operation
Accuracy ±1.0°C@200°C; ±0.8°C@1000°C, total memory 130,000 data points over
10 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 110°C.
Uses replaceable high operating temperature Lithium batteries (4).
Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H).
USB communications cable supplied (CI1033).
TP2115-TM Tpaq21, 10 Channel data logger, range - 0°C to
+1760°C, type S, high ambient temp operation.With
integral TM21 RF transmitter
Accuracy ±1.0°C@200°C; ±0.8°C@1000°C, total memory 130,000 data points over
10 channels.
Sampling interval 0.1s to 50 min(no telemetry).
Sampling interval 1s to 50 min(with telemetry),
Maximum operating temperature 110°C.
Replaceable high operating temperature Lithium batteries (4).
Hot data protection.
200 mm (L) x 98 mm (W) x 20 mm (H).
TM21 Transmitter TX1401.
High temp signal drift compensation.
USB comms cable.
TP2185 Tpaq21, 8 Channel data logger, temperature
measuring range - 0°C to +1760°C, type S, high
ambient temperature operation
Accuracy ±1.0°C@200°C; ±0.8°C@1000°C, total memory 130,000 data points over
8 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 110°C.
Uses replaceable high operating temperature Lithium batteries (4).
Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H).
USB communications cable supplied (CI1033).
KILN LOGGERS TYPE B
TP2018 Tpaq21, 10 Channel data logger, temperature
measuring range 55°C to +1815°C, type B, 70°C
ambient temperature operation
Accuracy ±1.0°C at 1500°C ±3°C at 400°C, total memory 130,000 data points over
10 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 70°C.
Uses rechargeable NiMH battery complete with charger.
Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H).
USB communications cable supplied (CI1031).
TP2018-TM Tpaq21, 10 Channel data logger, range 55°C to
+1815°C, type B, 70°C ambient temp operation. With
integral TM21 RF transmitter
Accuracy ±1.0°C at 1500°C ±3°C at 400°C, total memory 130,000 data points over
10 channels.
Sampling interval 0.1s to 50 min(no telemetry).
Sampling interval 1s to 50 min (with telemetry),
Maximum operating temperature 70°C.
Rechargeable NiMH battery and charger.
Hot data protection.
200 mm (L) x 98 mm (W) x 20 mm (H).
TM21 Transmitter TX1401.
Has high temp signal drift compensation.USB comms cable.
TP2088 Tpaq21, 8 Channel data logger, temperature
measuring range 55°C to +1815°C, type B, 70°C
ambient temperature operation
Accuracy ±1.0°C at 1500°C ±3°C at 400°C, total memory 130,000 data points over
8 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 70°C.
Uses rechargeable NiMH battery complete with charger.
Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H).
USB communications cable supplied (CI1031).
TP2118 Tpaq21, 10 Channel data logger, temperature
measuring range 55°C to +1815°C, type B, high
ambient temperature operation
Accuracy ±1.0°C at 1500°C ±3°C at 400°C, total memory 130,000 data points over
10 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 110°C.
Uses replaceable high operating temperature Lithium batteries (4).
Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H).
USB communications cable supplied (CI1033).
TP2118-TM Tpaq21, 10 Channel data logger, range 55°C to
+1815°C, type B, high ambient temp operation. With
integral TM21 RF transmitter
Accuracy ±1.0°C at 1500°C ±3°C at 400°C, total memory 130,000 data points over
10 channels.
Sampling interval 0.1s to 50 min(no telemetry),
Sampling interval 1s to 50 min(with telemetry),
Maximum operating temperature 110°C.
Replaceable high operating temp Lithium batteries (4).
Hot data protection.
200 mm (L) x 98 mm (W) x 20 mm (H).
TM21 Transmitter TX1401.
High temp signal drift compensation.
USB comms cable.
TP2188 Tpaq21, 8 Channel data logger, temperature
measuring range 55°C to +1815°C, type B, high
ambient temperature operation
Accuracy ±1.0°C at 1500°C ±3°C at 400°C, total memory 130,000 data points over
8 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run.
Maximum ambient operating temperature 110°C.
Uses replaceable high operating temperature Lithium batteries (4).
Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H).
USB communications cable supplied (CI1033).
TPAQ6 DATA LOGGERS
TP2164 Tpaq6, 6 Channel data logger, temperature measuring
range 0°C to +1760°C, type R, high ambient
temperature operation.
Accuracy ±1.0°C@200°C; ±0.7°C@1000°C, total memory 60,000 data points over
6 channels.
Sampling interval 1second to 60 minutes.
Maximum ambient operating temperature 110°C.
Uses replaceable high operating temperature Lithium batteries (4).
Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H).
USB communications cable supplied.
TP2165 Tpaq6, 6 Channel data logger, temperature measuring
range 0°C to +1760°C, type S, high ambient
temperature operation.
Accuracy ±1.0°C@200°C; ±0.8°C@1000°C, total memory 60,000 data points over
6 channels.
Sampling interval 1second to 60 minutes.
Maximum ambient operating temperature 110°C.
Uses replaceable high operating temperature Lithium batteries (4).
Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H).
USB communications cable supplied.
TP2166 Tpaq6, 6 Channel data logger, temperature measuring
range -100°C to +1370°C, type K, high ambient
temperature operation.
Accuracy ± 0.3°C, total memory 60,000 data points over 6 channels.
Sampling interval 1second to 60 minutes.
Maximum ambient operating temperature 110°C.
Uses replaceable high operating temperature Lithium batteries (4).
Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H).
USB communications cable supplied.
  KILN THERMAL BARRIERS
TB6100-K10 Phased Evaporation Thermal Barrier, Type K, 10
Channel.
Stainless Steel construction with graduated insulation layers around water jacket
and inside barrier.
Suitable logger: TP2116.
10 type K thermocouple channels, rated to 400°C max.
operating temperature.
Available for type R, S or B (TB6100-R10 … etc).
Duration: 250 hours at 150°C average under car temperature, 75 hours at 250°C
average under car temperature.
Dimensions: 180mm(H) x 350mm(W) x 480mm(L).
Weight: 20kg (empty), 27.25kg (full)
TB6100-K20 Phased Evaporation Thermal Barrier, Type K, 20
Channel.
Stainless Steel construction with graduated insulation layers around water jacket
and inside barrier.
Suitable loggers: 2 x TP2116.
10 type K thermocouple channels, rated to 400°C max operating temperature.
Available for type R, S or B (TB6100-R20 … etc)
Duration: 250 hours at 150°C average under car temperature, 75 hours at 250°C
average under car temperature.
Dimensions: 180mm(H) x 350mm(W) x 480mm(L).
Weight 20kg ( empty), 27.25kg (full).
TB6200-K10 Phased Evaporation Thermal Barrier, Type K, 10
Channel.
Stainless Steel construction with graduated insulation layers around water jacket
and inside barrier.
Suitable logger: TP2116.
10 type K thermocouple channels, rated to 400°C max operating temperature.
Available for type R, S or B (TB6200-R10 … etc).
Duration: 150 hours at 150°C average under car temperature, 56 hours at 250°C
average under car temperature.
Dimensions: 155mm(H) x 280mm(W) x 430mm(L).
Weight: 13.5kg (empty), 18.5kg (full).
TB6200-K20 Phased Evaporation Thermal Barrier, Type K, 20
Channel.
Stainless Steel construction with graduated insulation layers around water jacket
and inside barrier.
Suitable loggers: 2 x TP2116.
20 type K thermocouple channels, rated to 400°C max operating temperature.
Available for type R, S or B (TB6200-R20 … etc)
Duration: 150 hours at 150°C average under car temperature, 56 hours at 250°C
average under car temperature.
Dimensions: 155mm(H) x 280mm(W) x 430mm(L).
Weight: 13.5kg (empty), 18.5kg (full).
TB6400-K10 Thermal Barrier. Phased evaporation. Stainless Steel
construction. Specifically designed for the Pottery
Industry, 10 Channel
Suitable logger TP2116.
Duration: 98 hrs @150°C, 48 hrs @200°C, 30 hrs @250°C, 20 hrs @300°C, 12 hrs
@400°C.
Available for type R, S or B (TB6400-R10 … etc).
Dimensions:120mm (H) x 200mm (W) x 370mm (L).
Weight: 7.25kg (empty), 9.75kg (full).
TB6400-K8 Thermal Barrier. Phased evaporation. Stainless Steel
construction. Specifically designed for the Pottery
Industry, 8 Channel.
Suitable logger TP2186.
Duration: 98 hrs @150°C, 48 hrs @200°C, 30 hrs @250°C, 20 hrs @300°C, 12 hrs
@400°C.
Available for type R, S or B (TB6400-R8 … etc).
Dimensions:120mm (H) x 200mm (W) x 370mm (L).
Weight: 7.25kg (empty), 9.75kg (full).
TB6400-S10 Thermal Barrier for Pottery/Sanitaryware Industry.
Phased evaporation. S/S construction. 10 Channel.
Type S thermocouple
Suitable logger TP2115.
Duration: 98 hours @150°C, 48 hours @200°C, 30 hours @250°C, 20 hour
@300°C, 12 hours @400°C.
Available on request with Type R and B thermocouples.
Dimensions:120mm (H) x 200mm (W) x 370mm (L).
Weight: 7.25kg (empty), 9.75kg (full).
SPECIAL BARRIERS TUNNEL KILN
TB3049 Phased Evaporation Thermal Barrier.
Designed for use in clay block and small sanitaryware applications.
Stainless Steel construction with graduated insluation layers around a water jacket.
Suitable Data Logger: Tpaq6 (TP2164; TP2166) or Tpaq21 (TP2186; TP2116).
Requires: TB3049A7 (x2) and CS3087 (x4).
Duration: 45 hours @ 150°C; 30 hours @ 200°C; 18 hours @ 250°C.
Dimensions: 100mm (H) x 204mm (W) x 415mm (L).
Weight: 7.2kg (empty); 10kg (full).
TB3801 Standard Kiln Thermal Barrier, 8 Channel, Type K
Thermocouple.
Stainless Steel construction, ceramic insulation, includes heatsink.
Suitable logger TP2086.
Duration: 119 hours@100°C, 40 hours@200°C.
(Early design superseded by TB6100; TB6200)
Dimensions: 500mm(L) x 420mm(W) x 256mm(H).
Weight: 40kg
TB3802 Slim Kiln Thermal Barrier, 8 Channel, Type K
Thermocouple.
Stainless Steel construction, ceramic insulation, includes heatsink.
Suitable logger TP2086.
Duration: 40 hours@100°C, 13 hours@200°C.
(Early design superseded by TB6400).
Dimensions: 360mm(L) x 279mm(W) x 177mm(H).
Weight 15kg
TB3808 Whiteware Thermal Barrier, Type R/S.
Stainless Steel construction, Ceramic insulation, type R/S thermocouples, includes
heatsink.
Suitable logger: TP2084/TP2085.
(Early design superseded by TB6400).
Duration: 50 hours @ 100°C, 17 hours @ 200°C.
Dimensions: 500mm(L) x 296mm(W) x 170mm(H).
Weight 22kg
TB3823 Thermal Barrier, Type K.
Stainless Steel construction, ceramic insulation, includes heatsink.
Replacement for competitors system.
For use in skate kiln.
Suitable logger: TP2086.
Duration: 17.5hrs @100°C, 5 hours at 200°C, 4 hours at 250°C.
Dimensions: 210mm(H) x 192mm(W) x 260mm(L).
Weight 8kg
TB3829 Special Thermal Barrier, Type K, 8 Channel
Stainless steel construction.
Suitable for kilns with low undercar temperatures.
Suitable logger: TPaq21.
Not for use over 100°C.
Dimensions: 176mm(H) x 95mm(W) x 260mm(L).
Weight 4.35kg
TB6300-K10 Phased Evaporation Thermal Barrier, Type K, 10
Channel.
Stainless Steel construction with graduated insulation layers around water jacket
and inside barrier.
Suitable logger: TP2116
10 type K thermocouple channels, rated to 400°C maximum operating temperature.
Available on request with type R, S or B.
Duration: 140 hours at 150°C average under car temperature, 46 hours at 250°C
average under car temperature.
Dimensions: 130mm(H) x 280mm(W) x 420mm(L).
Weight 12kg (empty), 16kg (full).
SPECIAL BARRIERS HYDRO KILN
TB3043 10 Channel Thermal Barrier for Hydro Kiln.
Waterproof enclosure, Type K Thermocouple's.
Suitable logger TP2016.
Maximum Water Temperature 65°C.
Dimensions 269mm(L) x 224mm(W) x 177mm(H).
Weight: 15kg.
TB3805 8 channel Thermal Barrier for Hydro Kiln Systems.
Waterproof enclosure, type K thermocouple.
Suitable logger TP2086.
Duration: Maximum water temperature 65°C.
Dimensions: 269mm(L) x 224(W) x 177mm(H).
Weight: 15kg.
TB6500-K16/20 Special Barrier, 16 or 20 Channel for Standard or
Hydro Kiln.
Removable remote thermocouple sockets (for use in
Hydro Kiln).
Waterproof Stainless Steel construction with graduated insulation layers around
water jacket and inside barrier.
Suitable logger: 2 x TP2186 or 2 x TP2116 (Type K).
Rated to 300°C maximum operating temperature.
Available on request with Type R, S or B.
Duration: 98 hours at 150°C average under car temperature, 30 hours at 250°C
average under car temperature.
Dimensions: 153mm(H) x 280mm(W) x 480mm(L).
Weight: 16kg (empty), 19kg (full).
TB6500-K8/10 Special Barrier, 8 or 10 Channel, for Standard or
Hydro Kiln.
Removable remote thermocouple sockets (for use in
Hydro Kiln).
Waterproof Stainless Steel construction with graduated insulation layers around
water jacket and inside barrier.
Suitable logger: 1 x TP2186 or 1 x TP2116 (Type K).
Rated to 300°C maximum operating temperature.
Available on request with Type R, S or B.
Duration: 98 hours at 150°C average under car temperature, 30 hours at 250°C
average under car temperature.
Dimensions: 153mm(H) x 280mm(W) x 480mm(L).
Weight: 16kg (empty), 19kg (full).
  SPECIAL BARRIERS ROLLER HEARTH KILN
TB3045 Special RHK Sanitaryware Thermal Protection System.
Thermal Barrier specifically designed for roller hearth kiln.
Suitable logger: TP2116/TP2119.
Comprises: TB3046 Phased Evaporative Water Tank, TB3047 Insulation Frame,
CS3064 Template Set, CS2064 Insulation Set.
Duration: 17 hours @ average of 900°C, maximum 1100°C, 20 hours @ average of
700°C, maximum 1100°C.
Dimensions 450mm(H) x 360mm(W) x 400mm(L).
Weight: 30.65kg (empty), 49kg (full).
TB3050 Special RHK Sanitaryware Thermal Protection System.
Recommended Data Logger: TP2116.
Comprises: TB3051 Evaporative Tank, TB3052 Insulation Cage, CS3082 Template
Set, CS2064 Insulation Set.
Duration: 12 hours at 700°C average, 1200°C max.
Dimensions: 330mm(H) x 345mm(W) x 600mm(L).
Weight: 29kg (empty), 37kg (full).
  ROLLER HEARTH KILN BARRIERS
TB3020 Thermal Protection System for Tile Roller Hearth Kiln.
Suitable logger: TP2186.
Includes Stainless Steel Evaporative Water Tank (TB3021), Insulation Frame
(KL1428), constructed from high grade temperature resistant steel, Ceramic Board
(CS1093A) and Insulation Set (KL1431).
Duration: 1 hour at an average of 700°C, max 1200°C.
30 min.at an average of 900°C, max 1200°C.
Dimensions: 67mm(H) x 360mm(W) x 638mm(L).
Add 10mm for ceramic board.
Weight: 10.5kg (empty) and 15kg (full).
TB3031 Special RHK Roof Tile Thermal Protection System.
Suitable logger: TP2116/TP2119.
Thermal Barrier specifically designed for roller hearth kilns.
Comprises: TB4076 Phased Evaporative Water Tank, TB4077 Insulation Frame,
CS2021 Template Set, CS2064 Insulation Set.
Duration: 5 hours @ average of 700°C, 3.5 hours @ average of 900°C.
Max temp 1200°C.
Dimensions 150mm(H) x 382mm(W) x 610mm(L).
Weight: 20kg (empty), 28kg (full).
TB3036 Special RHK Tableware Thermal Protection System.
Suitable logger: TP2116 / TP2119.
Thermal Barrier specifically designed for roller hearth kilns.
Comprises: TB4076 Phased Evaporation Water Tank, TB4079 Insulation Frame,
CS2028 Template Set, CS2064 Insulation Set.
Duration: 7 hours @ average of 700°C, 5 hours @ average of 900°C, Max Temp
1200°C.
Dimensions 200mm(H) x 432mm(W) x 660mm(L).
Weight: 24kg (empty), 32kg (full).
TB3038 Special RHK Sanitaryware Thermal Protection System.
Suitable logger: TP2116 / TP2119.
Comprising: TB3028 Phased Evaporative Water Tank, KL1440 Insulation Frame,
CS2064 Insulation Set, CS2053 Template Set.
Duration: 17 hours @ average of 700°C, 10 hours @ average of 900°C, max temp
1200°C.
Dimensions: 300mm(H) x 512mm(W) x 735mm(H).
Weight: 36.5kg (empty), 51 kg (full).
  RHK COMPONENTS AND ACCESSORIES
CB1122 Thermal Barrier Connector Interface (between 3mm
standard connector socket and thermocouple with
miniature connector).
Type K.
Resistance to 200°C.
CS1093 Ceramic Board Set for TB3020 (x 4).
500mm x 400mm x 10mm.
CS2021 Template Set for Insulation Retaining Frame TB4077.
To cut additional insulation panels for TB3031 Roof Tile Thermal Protection System.
CS2028 Template Set for Insulation Retaining Frame TB4079.
To cut additional insulation panels for TB3036 RHK Tableware Thermal Protection
System.
CS2053 Template Set for Insulation Retaining Frame KL1440.
To cut additional insulation panels for TB3038 RHK Sanitaryware Thermal
Protection System.
CS2064 Roll of Alumina Fibre Blanket, 7.2m length.
Blanket Insulation.
Specification: 25mm thick; 120kg/m³ density; maximum operating temperature
1600°C; thermal conductivity 0.27W/mK.
Note: Additional shipping cost applies to this item.
CS3064 Template Set for Insulation Retaining Frame TB3047.
To cut additional insulation panels for TB3045 special RHK Thermal Protection
System.
CS3082 Template Set for Insulation Retaining Frame TB3052.
To cut additional insulation panels for TB3050 RHK Sanitaryware Thermal
Protection System.
KL1431 Insulation Set (x 4).
Insulation blanket, shaped to suit thermal protection system TB3020.
KL1440 Insulation Retaining Frame.
For use with TB3036/ TB3038 Sanitaryware Thermal Protection System.
TB3021 Phased Evaporative Water Tank
For use with TB3020 tile roller hearth kiln thermal protection system.
TB3028 Phased Evaporation Water Tank.
For use with TB3038 Special Sanitaryware Thermal Protection System.
TB4076 Phased Evaporation Water Tank.
For use with TB3031 Roof Tile Thermal Protection System, or TB3036 Special
Tableware Thermal Protection System.
TB4077 Insulation Retaining Frame.
For use with TB3031 Roof Tile Thermal Protection System.
TB4079 Insulation Retaining Frame.
For use with TB3036 Special Tableware Thermal Protection System.
TM21 KILN TELEMETRY SYSTEM KITS
TM21-ARX-10 Receiver Extension Antenna Set (10m Long)
Add on price for secondary receiver extension set using remote UGEF antenna to
extend receiving power for short continuous furnaces, ovens or kilns.
Extends range to 10 meters from base receiver.
Comprises:
1 x TM0200; TM21 Secondary Receiver Kit
(UGEF Antenna (RX1023 or RX1024), Secondary Receiver RX4X01 (Country
Specified)*, Receiver Antenna Stand RX1020 and UGEF Antenna and Receiver
Box Mounting Kit RX2502)
1 x TM1042 10 m RS485 Communication able
TM21-ARX-45 Receiver Extension Antenna Set (45m Long)
Add on price for secondary receiver extension set using remote UGEF antenna to
extend receiving power for short continuous furnaces, ovens or kilns.
Extends range to 45 meters from base receiver.
Comprises:
1 x TM0200; TM21 Secondary Receiver Kit
(UGEF Antenna (RX1023 or RX1024), Secondary Receiver RX4X01 (Country
Specified)*, Receiver Antenna Stand RX1020 and UGEF Antenna and Receiver
Box Mounting Kit RX2502) 1 x TM1045 45 m RS485 Communication Cable
TM21-KBRS Standard Kiln Transmitter and Base Reciever Set.
Add to Price of Kiln System, to provide RF operation using single reciever antenna
for Kiln Monitoring.Used with Receiver Extension Antenna Kit(s) to suit Kiln.
Comprises: 1*TM21-TX-UG fit TM21 transmitter to TPAQ21.
2*TM21 Logger Transmit Antenna (TX2020 Logger Connection OR TX2021 Barrier
Connection).1*TM21 Primary Reciever Kit TM0100 To suit Country.
(Primary Reciever, CH0070, Antenna RX1010 + terminator TM1060) 1*TM1046A
100m RS485 Cable

 

Kiln Pricelist April 2012 - Datapaq  Vietnam_ANS Vietnam Germany, USA, Asia, Vietnam, Singapore, Japan, Cambodia, Laos, Thailand, Myanmar, Indonesia, Malaysia, Singapore, China, India, Pakistan, Egypt, Iran, Jordan, Saudi Arabia, Sudan Syria, Iraq, Sudan.


Hãy liên hệ với chúng tôi để có được giá tốt nhất !

 

Công Ty TNHH TMDV Anh Nghi Sơn

| địa chỉ | D3, Đinh Tiên Hoàng, KDC Miếu Nổi, Phường 3, Quận Bình Thạnh, TPHCM

| mã số thuế | 0310692382

| điện thoại | + 84 . 8 . 3517 0401/02 | fax | +84 . 8 . 3517 0403

| email | sales.ans@ansvietnam.com ans.vina@ansvietnam.com

| website | www.ansvietnam.com www.anhnghison.com

| liên hệ trực tuyến | Skype | Yahoo