Takuwa Vietnam - Signal Converter (GICW Series)
Loại sản phẩm: Water Gate Indicator
Mã sản phẩm: Signal Converter (GICW Series)
Nhà cung cấp: Anh Nghi Sơn
Xuất Xứ: chính hãng
Hãng sản xuất: Takuwa
Giá : Vui lòng liên hệ
Signal Converter (GICW Series)
GICW series is a signal converter from Synchro to Digital for output to external equipment.
It has many useful functions for adjustment of gate opening indicator.
Non-linearity scale conversion table can be set up and it is suitable for the radial gate.
Features
- ・Conversion from the Synchro to the BCD signal (by Absolute value)
- ・Arbitray scale adjustment (Zero adjustment, Free scale, Level offset)
- ・Non-linearity scale conversion table can be set up easily by PC software and installed
it to the GICW through the SD card - ・Self-Diagnosing function (ERR code is displayed)
- ・Small size and lightweight
Available sites
-
・Water gate opening indicator which is using a synchronous motor
Main specification
Type | GICW-S1-□□ | GICW-S2-□□ | |
Power Supply
|
AC90V~AC242V, 50/60Hz
|
||
Current consumption
|
30VA or less
|
||
Ambient temperature
|
-10ºC ~ 50ºC
|
||
Data output rang
|
±99999
|
||
Conversion accuracy | ±0.1%FS | ±0.003%FS | |
Input signal | Synchro 3-wire signal Max.90V/Input synchro 1unit (1st gear) |
Synchro 3-wire signal Max.90V/Input synchro 2unit(2nd gear) |
|
Data output signal
|
1.BCD: 5digit x 2
-Each digit odd parity, BUSY, Signal error,Dropping voltage
-Output condition: A contact with non-voltage
2.RS-232C(no control sequence) x 1
3.Power discontinuity contact x 1
-Output condition: Make when electric outage
4.Compare contact: x 16
-Output condition: A contact with non-voltage |
||
Input scale conversion | 0~1999/Rev | 0~20000/Rev | |
Throughput performance
|
Level calculation: -999.99m~+999.99m
Hold: maximum / minimum
Zero point adjustment: by setting SW in the front of body
Data output direction can be set
Self-diagnosing trouble: power off, signal error, dropping voltage
Non-linearity scale conversion by correction table
|
||
SD card
|
Usable card: 2GB or less
|
||
Data transfer distance
|
Input: Max. 1km (2mm2 wire in use)
|
Options
Model name: GICW-[AB]-[CD]
Code | Option Type | Option Detail Number |
[AB] | Input signal | S1:Synchro 3-wire signal Max.90V/Input synchro 1unit S2: Synchro 3-wire signal Max.90V/Input synchro 2units |
[CD] | Output signal | 11: BCD Output x 1 Compare contact output x 1 20: BCD Output x 2 |