Takuwa Vietnam - Signal Converter (GICW Series) - - Thiết bị tự động hóa công nghiệp - ANS Vietnam

Hổ trợ trực tuyến

Click here to chat Skype Me™!
dieu.ans@ansvietnam.com

Ms Diệu: 0902.337.066

Menu sản phẩm

Hãng sản xuất

Lượt truy cập

Đang online 57
Lượt truy cập 4585147

Takuwa Vietnam - Signal Converter (GICW Series)

Loại sản phẩm: Water Gate Indicator

Mã sản phẩm: Signal Converter (GICW Series)

Nhà cung cấp: Anh Nghi Sơn

Xuất Xứ: chính hãng

Hãng sản xuất: Takuwa

Giá : Vui lòng liên hệ

Signal Converter (GICW Series)

GICW series is a signal converter from Synchro to Digital for output to external equipment.

It has many useful functions for adjustment of gate opening indicator.

Non-linearity scale conversion table can be set up and it is suitable for the radial gate.

     

Features

  •   ・Conversion from the Synchro to the BCD signal (by Absolute value)
  •   ・Arbitray scale adjustment (Zero adjustment, Free scale, Level offset)
  •   ・Non-linearity scale conversion table can be set up easily by PC software and installed
          it to the GICW through the SD card
  •   ・Self-Diagnosing function (ERR code is displayed)
  •   ・Small size and lightweight
     

Available sites

  •  ・Water gate opening indicator which is using a synchronous motor

Main specification

 

Type GICW-S1-□□ GICW-S2-□□
Power Supply
AC90V~AC242V, 50/60Hz
Current consumption
30VA or less
Ambient temperature
-10ºC ~ 50ºC
Data output rang
±99999
Conversion accuracy ±0.1%FS ±0.003%FS
Input signal Synchro 3-wire signal
Max.90V/Input synchro
1unit (1st gear)
Synchro 3-wire signal
Max.90V/Input synchro
2unit(2nd gear)
Data output signal
1.BCD: 5digit x 2
 -Each digit odd parity, BUSY, Signal error,Dropping voltage
 -Output condition: A contact with non-voltage
2.RS-232C(no control sequence) x 1
3.Power discontinuity contact x 1
 -Output condition: Make when electric outage
4.Compare contact: x 16
  -Output condition: A contact with non-voltage 
Input scale conversion 0~1999/Rev 0~20000/Rev
Throughput performance                
Level calculation: -999.99m~+999.99m
Hold: maximum / minimum
Zero point adjustment: by setting SW in the front of body
Data output direction can be set
Self-diagnosing trouble: power off, signal error, dropping voltage
Non-linearity scale conversion by correction table
SD card
Usable card: 2GB or less
Data transfer distance
Input: Max. 1km (2mm2 wire in use)


 

Options

 
  Model name: GICW-[AB]-[CD]

Code Option Type Option Detail Number
[AB] Input signal S1:Synchro 3-wire signal Max.90V/Input synchro 1unit
S2: Synchro 3-wire signal Max.90V/Input synchro 2units
[CD] Output signal 11: BCD Output x 1 Compare contact output x 1
20: BCD Output x 2

Sản phẩm liên quan

Takuwa Vietnam - Float Ty ...

Takuwa Vietnam - Limit Sw ...

Takuwa Vietnam - Wire-Spr ...

Takuwa Vietnam - Compact ...

Takuwa Vietnam - Water Re ...

Takuwa Vietnam - Shaft-Ro ...