gpr-1600-ms-series-sub-ppm-oxygen-analyzer

Loại sản phẩm: PH - ORP - Oxygen

Mã sản phẩm: gpr-1600-ms-series-sub-ppm-oxygen-analyzer

Nhà cung cấp: anh nghi sơn

Xuất Xứ: chính hãng

Hãng sản xuất: Aii

Giá : Vui lòng liên hệ

GPR-1600-MS sub-PPM oxygen analyzer utilizes the proprietary Pico-Ion oxygen sensor capable of precisely measuring oxygen concentrations ranging from 10 PPB to 1000 PPM over a 36 months operating sensor life with no periodic maintenance required, integral temperature control enhances stability, menu driven controls and a stainless steel integral bypass sample system that enables the analyzer to come online at low PPB levels in minutes.

Accuracy: < 2% of FS range under constant conditions Analysis Ranges: 0-1 PPM, 0-10 PPM, 0-100 PPM and 0-1000 PPM
Application: Oxygen analysis from 10 ppb to 1000 ppm in inert, helium, hydrogen, mixed gas streams  Area Classification: General purpose
Alarms: 2 adjustable form C relay contacts non-latching; “weak sensor” indicator; power failure; system failure Calibration: Certified gas of O2balance N2approximating 80% of analysis range or one range higher than analysis range
Compensation:  Barometric pressure and temperature; temperature controlled heated sample system Connections: 1/4″ compression tube fittings
Controls: Water resistant keypad; menu driven range selection, calibration, alarm and system functions Data Acquisition: Selectable data point intervals
Display: Graphical LCD 5 x 2.75; resolution .001 ppm Enclosure: Painted aluminum 7.5” x 10.8” x 12.25” panel mount
Flow Sensitivity: None between 1-3 SCFH, 1 SCFH recommended Linearity: > .995 over all ranges
Pressure: Inlet – regulate to 20-50 psig, max 150 psig; vent – atmosphere Power: Universal; specify 110 or 220 VAC for heater system
Range ID: 1-5V output with1V representing the lowest range Recovery Time: Recovery on N2 after exposure to Air for 30 seconds> 1 ppm 45 minutes
Response Time: 90% of final FS reading < 30 seconds Sample System: Wetted parts: stainless steel consisting of flow control and sample/bypass valves; flow indicator
Sensitivity: < 0.5% of FS range Sensor Model: GPR-12-2000MS – requires no maintenance
Sensor Life: 36 months at 25ºC and 1 atm Signal Output: 4-20mA isolated and 0-1VDC
Temp. Range: 5º to 45ºC Warranty: 12 months analyzer; 12 months sensor